 Use an inverter that conforms to the specifications of power supply and three-phase
Mandatory
 The leakage current through the input/output power cables of inverter and capacitance of
action
 When operation by using remote keypad is selected
 Set the parameter Communication time-out time (f803), Communication time-out
Mandatory
 An emergency stop device and the interlock that fit with system specifications must be
action
 When sequence for restart after a momentary failure is selected (inverter)
 Stand clear of motors and mechanical equipment.
Mandatory
 Attach caution label about sudden restart after a momentary power failure on inverters,
action
 When retry function is selected (inverter)
 Stand clear of motors and equipment.
Mandatory
 Attach caution label about sudden restart in retry function on inverters, motors and
action
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
induction motor being operated. If the inverter being used does not conform to those
specifications, not only will the three-phase induction motor not rotate correctly, but it will
cause serious accidents through overheating and fire.
motor can affect to peripheral devices.
The value of leakage current is increased under the condition of the PWM carrier
frequency and the length of the input/output power cables. In case the total cable length
(total of length between an inverter and motors) is more than 100m, overcurrent trip can
occur even the motor no-load current.
Make enough space among each phase cable or install the filter (MSF) as
countermeasure.
action (f804) and Disconnection detection of extension panel (f731).
If these are not properly set, the inverter can not be stopped immediately in breaking
communication and this could result in injury and accidents.
installed.
If these are not properly installed, the inverter can not be stopped immediately and this
could result in injury and accidents.
If the motor stops due to a momentary power failure, the equipment will start suddenly
after power is restored. This could result in unexpected injury.
motors and equipment for prevention of accidents in advance.
If the motor and equipment stop when the alarm is given, selection of the retry function will
restart them suddenly after the specified time has elapsed. This could result in unexpected
injury.
equipment for prevention of accidents in advance.