Toshiba VF-S15 Instruction Manual page 51

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

2.2.2
Main circuit power supply
3ph-240V class: three-phase 200-240V
1ph-240V class: single-phase 200-240V
3ph-500V class: three-phase 380-500V
MCCB(2P)
Single
phase
Power
supply
*1: The T/L3 terminal is not provided for
single-phase models.
Use the R/L1 and S/L2/N terminals as
input terminals.
*2: The inverter is supplied with the PO
and the PA/+ terminals shorted by
means of a shorting bar.
Before installing the DC reactor (DCL),
remove the bar.
*3: When using the NO output terminal in
source logic mode, short the P24 and
OUT terminals.
*4: When VIA or VIB terminal is used as logic
input terminal, refer to section 7.2.1.
*5: To supply control power from an external
power supply for backing up the control
power supplied from the inverter, an optional
control power backup device (CPS002Z) is
required. In such a case, the backup device
is used at the same time with the internal
power supply of the inverter.
The optional control power backup unit can
be used with both 240V and 500V models.
*6: Set the slide switch SW1 to source side.
Refer to page B-11,12 for details.
Default setting is PLC side.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Standard connection diagram 2
Standard connection diagram - SOURCE (Positive) (common:P24)
DC reactor (DCL)
*2 (option)
*1
MCCB
R/L1
-50/60Hz
S/L2
-50/60Hz
T/L3
-50/60Hz
+24
+SU
Control power
supply
CC
R/L1
*5
VF-S15
S/L2/N
FLA
Protective function
FLB
activation output
FLC
RY
Low-speed
signal output
RC
FM
Meter
Frequency
meter
(ammeter)
1mA
(or 0(4)-20mA/0-10V)
P0
PA/+
PB
PC/-
Noise
Power circuit
filter
Control
circuit
Operation panel
*6
SW1
SINK
SOURCE
PLC
RS485
SW2
connector
S4
VIB
S3
PTC
*4
*4
CC
VIC
VIB
VIA
PP
+
-
External potentiometer (1k-10k)
(or voltage signal between VIA and CC: 0-10V)
B-5
E6581611
Braking resistor(Option)
Motor
U/T1
V/T2
M
W/T3
F
Forward run command
R
Reverse run command
RES
Reset
Preset-speed command 1
S1
S2
Preset-speed command 2
S3
Preset-speed command 3
Common
P24
*3
OUT
NO
Ry
Speed reach
signal output
CC
Current signal: 4(0)-20mA
Voltage signal: 0-+10V
(or -10-+10V)