6.34.6 Change display of the status monitor
f711 to f718 : Status monitor 1 to 8
Change monitor display items in the status monitor mode.
 Refer to chapter 8 for details.
6.34.7 Change the status monitor condition
f709 : Standard monitor hold function
f746 : Status monitor filter
 Function
6
● If  is set to , the monitored values selected with  (standard monitor display selection
parameter) are displayed. For peak hold values and minimum hold values, the minimum values in each
operation cycle are displayed. When the motor is at a standstill, the values monitored last are held as they
were until the motor is started the next time.
The maximum and minimum values monitored after power is turned on is always displayed no matter
whether the motor is in operation or at a standstill.
The maximum and minimum values are cleared to press the EASY key by setting f750 to 3 .
● "Output current", "Input voltage", "Output voltage" and "Torque" can be filtered by f746 .
 Refer to chapter 8 about status monitor.
[Parameter setting]

f746
f750
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
The standard monitor display can be hold.
Some status monitors can be filtered to display.
Title
Function
Standard monitor hold function
Status monitor filter
EASY key function selection
Adjustment range
0: Real time
1: Peak hold
2: Minimum hold
8-1000 (ms)
0: Easy / standard setting mode switching
function
1: Shortcut key
2: Local / remote key
3: Monitor peak / minimum hold trigger
4: -
5: -
F-130
E6581611
Default setting
0
200
0