Toshiba VF-S15 Instruction Manual page 261

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

 List of logic input terminal function settings
Parameter
programmed value
Positive
logic





 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
*2: Active when  (frequency setting mode selection) =  (UP/DOWN from external logic input) is set.
The frequency setup range is from  to  (maximum frequency). The acceleration/deceleration time
relative to the set frequency is / while the acceleration/deceleration speed is not switched.
● Refer to section 11.6 for details about the input terminal function.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Function
Negative
logic

No function

Forward run command

Reverse run command

Standby

Reset command
 
Preset-speed command 1
 
Preset-speed command 2
 
Preset-speed command 3
 
Preset-speed command 4
 
Jog run mode
 
Emergency stop by external signal
 
DC braking command
 
2nd acceleration/deceleration
 
3rd acceleration/deceleration
 
2nd V/F control mode switching
 
2nd stall prevention level
 
PID control prohibition
 
External thermal error input
 
Forced local from communication
 
Operation hold (hold of 3-wire operation)
 
PID integral/differential clear
 
PID characteristics switching
 
Forced run operation
 
Fire speed operation
 
Acceleration/deceleration suspend signal
 
Power failure synchronized signal
 
Factory specific coefficient *1
 
Factory specific coefficient *1
Parameter
programmed value
Positive
Negative
logic
logic
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 to 


 
 
 
 
G-5
E6581611
Function
Integrating wattmeter (kWh) display
clear
Trace back trigger signal
Light-load high-speed operation
prohibitive signal
Holding of RY-RC terminal output
Holding of OUT-NO terminal output
Frequency UP *2
Frequency DOWN *2
Clear frequency UP/DOWN *2
Coast stop command
Forward/reverse selection
Run/Stop command
Frequency reference command forced
switching
Frequency setting mode terminal block
Command mode terminal block
Parameter editing permission
Fast stop command 1
Fast stop command 2
Traverse permission signal
Low voltage operation
Forward deceleration
Forward stop
Reverse deceleration
Reverse stop
Factory specific coefficient *1
No.2 motor switching
Parameter editing prohibition
Parameter reading prohibition
7

Hide quick links: