Chapter 2 - Operation
2.2.2

Procedure for Setting Data (LCD Keypad)

1. Press [MODE] key until the desired parameter group is displayed.
2. Press [? ] or [? ] keys to move to the desired parameter code. If you know the desired parameter code, you can
set the code number of each parameter group in " Jump code" , except DRV group.
3. Press [PROG] key to go into the programming mode, the cursor starts blinking.
4. Press [SHIFT/ESC] key to move the cursor to the desired digit.
5. Press [? ] or [? ] keys to change the data.
6. Press [ENT] key to enter the data. The cursor stops blinking.
n Note: Data cannot be changed when:
1) The parameter is not adjustable during the inverter is running. (Refer to the function table in Chapter 5) or
2) Parameter Lock function is activated in FU2-94 [Parameter Lock].