LG SV-iS5 Instruction Manual page 73

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

Code
Description
Fault Output Relay
I/O-45
Setting (30A, 30B, 30C)
I/O-46
26
Inverter Number
I/O-47
Baud Rate
Operating selection at
I/O-48
Loss of Freq. Reference
Waiting Time after Loss
I/O-49
of Freq. Reference
Auto (Sequence)
I/O-50
Operation selection
Sequence Number
I/O-51
Selection
The Number of Steps of
I/O-52
Sequence Number #
1
Step Frequency of
st
I/O-53
27
Sequence 1
Transient Time to 1
I/O-54
of Sequence 1
Steady Speed Time at 1
I/O-55
Step of Sequence 1
Motor Direction of 1
I/O-56
Step of Sequence 1
1
Step Frequency of
st
I/O-57
Sequence 2
Transient Time to 1
I/O-58
of Sequence 2
Steady Speed Time at 1
I/O-59
Step of Sequence 2
Motor Direction of 1
I/O-60
Step of Sequence 2
I/O-85
Step Frequency 8
I/O-86
Step Frequency 9
I/O-87
Step Frequency 10
I/O-88
Step Frequency 11
I/O-89
Step Frequency 12
26
Code I/O-46 through I/O-49 are used in Option Board like RS485, Device, Net and F-net etc.
27
The ' Seq#' of code I/O-53 through I/O-60 varies according to the sequence number selected in I/O-51.
The parameter code may be extended to I/O-84 depending the number of steps set in I/O-52 because the steps can be set up to 8.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Keypad Display
LCD
7-Segment
Relay mode
Inv No.
Baud rate
Lost command
Time out
Auto mode
Seq select
Step number
Seq1 / 1F
st
Step
Seq1 / 1T
st
Seq1 / 1S
st
Seq1 / 1D
Seq1 / 2F
st
Step
Seq1 / 2T
st
Seq1 / 2S
st
Seq1 / 2D
Step freq-8
Step freq-9
Step freq-10
Step freq-11
Step freq-12
Setting Range
LCD
7-Segment
000 to 111
45
(Bit Set)
1 to 31
46
1200 bps
2400 bps
4800 bps
47
9600 bps
19200 bps
None
FreeRun
48
Stop
0.1 to 120 [sec]
49
None
Auto-A
50
Auto-B
1 to 5
51
1 to 8
52
0.01 to FU1-20
53
0.1 to 6000 [sec]
54
0.1 to 6000 [sec]
55
Reverse
56
Forward
0.01 to FU1-20
57
0.1 to 6000 [sec]
58
0.1 to 6000 [sec]
59
Reverse
60
Forward
0 to FU1-20
85
86
87
88
89
67
Chapter 5 - Parameter List
Adj.
Factory
During
Units
Default
Run
-
010
Yes
1
1
Yes
0
1
-
9600 bps
Yes
2
3
4
0
-
None
Yes
1
2
0.1
1.0 [sec]
Yes
0
-
None
No
1
2
1
1
Yes
1
2
Yes
0.01
11.00 [Hz]
Yes
0.1
1.1 [sec]
Yes
0.1
1.1 [sec]
Yes
0
-
Forward
Yes
1
0.01
21.00 [Hz]
Yes
0.1
1.1 [sec]
Yes
0.1
1.1 [sec]
Yes
0
-
Forward
Yes
1
0.01
20.00 [Hz]
Yes
10.00 [Hz]
Yes
20.00 [Hz]
Yes
30.00 [Hz]
Yes
40.00 [Hz]
Yes
Page
133
133
133
133
134
135
135
126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents