Chapter 6 - Parameter Description [EXT]

6.5 External Group [EXT]

EXT group appears only when an optional Sub-Board is
installed.
EXT-00: Jump to Desired Code #
EXT?
Jump code
00
1
Factory Default:
1
Jumping directly to any parameter code can be
accomplished by entering the desired code number. This
code is available only with LCD keypad.

EXT-01: Sub-Board Display

EXT?
Sub B/D
01
None
Factory Default:
None
This code automatically displays the kind of Sub-Board
installed.
Setting Range
LCD
7-Seg
This board provides three multi- function
input terminals (P4, P5, P6), three multi-
Sub-A
1
function output terminals (Q1, Q2, Q3),
Load meter output (LM) and second input
frequency reference (V2).
This board provides encoder input terminals
(AOC, BOC / A+, A-, B+, B-), encoder
2
Sub-B
output terminals (FBA, FBB) and power
terminals (+5V input, Vcc output).
This board provides three multi- function
input terminals (P4, P5, P6), one multi-
Sub-C
3
function output terminal (Q1), isolated
second input frequency reference (V2) and
two analog meters (AM1, AM2).
See ' Chapter 7 - Options' for more detail descriptions.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
01
0
0
Description
136
EXT-02 ~ EXT-04: Multi-Function Input Terminal
Define (P4, P5, P6) – Sub-A, Sub-C
EXT?
P4 define
02
XCEL-L
Factory Default:
XCEL-L
An optional Sub-Board is needed if an application
requires more than three multi-function input terminals.
' Sub-A' and ' Sub-C' boards provide additional three
multi-function terminals. These terminals are used in
conjunction with P1, P2 and P3 terminals. Refer to I/O-
12 ~ I/O-14 for use. The following table shows the
terminal definitions.
Setting Range
LCD
7-Seg
0
Speed-L
Multi-Step Speed - Low
1
Speed-M
Multi-Step Speed - Mid
2
Speed-H
Multi-Step Speed - High
3
XCEL-L
Multi-Accel/Decel - Low
4
XCEL-M
Multi-Accel/Decel - Mid
5
XCEL-H
Multi-Accel/Decel - High
6
Dc-brake
DC injection braking during stop
7
2nd Func
Exchange to 2
8
Exchange
Exchange to commercial power line
9
-Reserved-
Reserved for future use
10
Up
Up drive
11
Down
Down drive
12
3-Wire
3 wire operation
13
Ext Trip-A
External trip A
14
Ext Trip-B
External trip B
15
iTerm Clear
Used for PID control
Exchange between PID mode and
Open-loop
16
V/F mode
Exchange between Option and
Main-drive
17
Inverter
18
Analog hold
Hold the analog input signal
19
XCEL stop
Disable accel and decel
20
P Gain2
Used for PID control
21
SEQ-L
Sequence operation - Low
22
SEQ-M
Sequence operation - Mid
23
SEQ-H
Sequence operation - High
Exchange between Sequence
24
Manual
operation and Manual operation
Triggering Sequence operation
25
Go step
(Auto-B)
26
Hold step
Hold last step (Auto-A)
27
Trv Off.Lo
Used for Traverse Operation
28
Trv Off.Hi
29
Interlock1
30
Interlock2
Used for MMC operation
31
Interlock3
32
Interlock4
Speed-X
33
Additional Step frequency selection
Reset
34
Reset
02
3
3
Description
functions
nd

Hide quick links: