I/O-53 - I/O-84: Frequency, Transient Time, Steady Speed Time, Motor Direction Setting Of Each Step And Sequence; I/O-85 - I/O 97: Step Frequency 8, 9, 10, 11, 12, 13, 14, 15, Multi-Function Input Terminal Rst, Bx, Jog, Fx, Rx Define - LG SV-iS5 Instruction Manual

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

[AUTO B]
This mode can be also used to program up to 8 different
steps as Auto A. However, to switch from one step to
another, an external contact closure set to ' Go step' is
required.
Output Frequency
Sequence 1
SEQ1 / 2F
SEQ2 / 2F
SEQ1 / 1F
SEQ3 / 2F
SEQ3 / 1F
P1-CM
ON
' SEQ-L'
P2-CM
' SEQ-M'
P3-CM
ON
ON
ON
' Go step'
[Example of ' Auto-B' operation]
Note: When a new sequence is selected during a
sequence operating, the new sequence starts after the
current sequence is finished.
I/O-53 ~ I/O-84: Frequency, Transient Time,
Steady Speed Time, Motor Direction setting of
each Step and Sequence
These parameter codes set the frequency, transient time,
steady speed time, and motor direction. These codes
are displayed according to the sequence number and
steps.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Sequence 3
Sequence 2
ON
ON
ON
Minimum 100msec
Chapter 6 - Parameter Description [I/O]
I/O-85~ I/O 97: Step frequecy 8, 9, 10, 11, 12, 13,
14, 15, Multi-function input terminal RST, BX,
JOG. FX, RX Define
See the description pages of I/O 21~39 for more details.