Control Method
Frequency Setting
Resolution
Frequency Accuracy
V/F Ratio
Overload Capacity
Torque Boost
Operation Method
Frequency Setting
Start Signal
Multi-Step
Multi Step Accel/Decel
Time
Emergency Stop
Jog
Auto Operation
Fault Reset
Operating Status
Fault Output
Indicator
Operation Function
Inverter Trip
Inverter Alarm
Momentary Power Loss
Operation
Keypad
Information
Trip Information
Ambient Temperature
Storage Temperature
Ambient Humidity
Altitude - Vibration
Application Site
Cooling Method
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
V/F Control, Sensorless Vector Control, Sensored Vector Control (Velocity, Torque) Selectable
Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)
Analog Reference: 0.03 Hz / 60 Hz
Digital: 0.01 % of Max. Output Frequency
Analog: 0.1 % of Max. Output Frequency
Linear, Squared Pattern, User V/F
150 % of Rated Current for 1 Min., 200% of Rated Current for 0.5 sec. (Characteristic is
Inversely Proportional to Time)
Manual Torque Boost (0 ~ 15 % ), Auto Torque Boost
Key / Terminal / Communication Operation
Analog: 0 ~ 10V / 4 ~ 20mA / Additional port for Sub-Board (0 ~ 10V)
Digital: Keypad
Forward, Reverse
Up to 8 Speeds can be Set (Use Multi-Function Terminal)
0 ~ 6,000 sec, Up to 4 Types can be Set and Selected for Each Setting (Use Multi- Function
Terminal). Accel/Decel Pattern: Linear, U-Curve, S-Curve
Interrupts the Output of Inverter
Jog Operation
Operates from Internal Sequence by Setting Multi-Function Terminal (5 Way * 8 Step)
Trip Status is Removed when Protection Function is Active
Frequency Detection Level, Overload Alarm, Stalling, Over Voltage, Under Voltage, Inverter
Overheating, Running, Stop, Constant Speed, Inverter By-Pass, Speed Searching, Auto-
Operation Step, Auto-Operation Sequence
Contact Output (30A, 30C, 30B) – AC250V 1A, DC30V 1A
Choose 1 from Output Frequency, Output Current, Output Voltage, DC Voltage, Output Torque
(Output Voltage: 0 ~ 10V)
DC Braking, Frequency Limit, Frequency Jump, Second Function, Slip Compensation, Reverse
Rotation Prevention, Auto Restart, Inverter By-Pass, Auto-Tuning, PID Control
Over Voltage, Under Voltage, Over Current, Fuse Open, Ground Fault, Inverter Overheating,
Motor Overheating, Output Phase Open, Overload Protection, External Fault 1, 2,
Communication Error, Loss of Speed Command, Hardware Fault, Option Fault, Overspeed,
M/C Fail etc.
Stall Prevention, Overload Alarm, Temperature Sensor Fault
Auto Restart function activated when FU2-21 [Restart after fault reset] set to 1 (Yes)
Output Frequency, Output Current, Output Voltage, Frequency Value Setting, Operating
Speed, DC Voltage, Output Torque
Indicates a Fault when the Protection Function activates, Retains Up to 5 Faults
-10 ° C ~ 40 ° C (14 ° F ~ 104 ° F), CE Certification: 41 °F ~ 104 °F (5 °C ~ 40 °C)
-20 ° C ~ 65 ° C (-4 ° F ~ 149 ° F)
Less Than 90 % RH Max. (Non-Condensing), CE Certification: 5 ~85% (Non-Condensing)
Below 1,000m or 3,300ft ・ Below 5.9m/sec
No Corrosive Gas, Combustible Gas, Oil Mist, or Dust
Forced Air Cooling
5
(=0.6g)
2