Ext-12: Usage Of Pulse Input Signal - Sub-B - LG SV-iS5 Instruction Manual

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

Chapter 6 - Parameter Description [EXT]
Reference Frequency
EXT-10
EXT-08
EXT-07
[Reference Frequency vs. Analog Voltage Input, V2 (0 to 10V)]
Related Functions:
DRV-04 [Frequency Mode]
I/O-01 ~ I/O-05 [V1 Adjustment]
EXT-12: Usage of Pulse Input Signal – Sub-B
EXT?
F mode
12
None
Factory Default:
None
This function is to select the usage of encoder pulse
signal of ' Sub-B' board. The pulse signal from encoder
can be used as the motor speed feedback or frequency
reference.
[None]
The encoder pulse signal is not used.
[Feed-back]
The encoder pulse signal is used as the motor speed
feedback. The inverter can maintain the motor speed
constantly, regardless of the load fluctuation, by using
the encoder feedback. Set the encoder pulse method
and the number of pulse in EXT -15 and 16. Main speed
is set in DRV-04 [Frequency mode]. The encoder pulse
related functions must be set correctly for better
performance in EXT -15 ~ EXT -24.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Analog Voltage
Input (V2)
EXT-09
12
0
0
138
Code
LCD Display
EXT-12
F mode
EXT-15
F pulse set
EXT-16
F pulse num
EXT-22
PG P-gain
EXT-23
PG I-gain
EXT-24
PG Slip Freq
EXT-25
ASR P-Gain
EXT-26
ASR I-Gain
EXT-27
Trq + Limit
EXT-28
Trq – Limit
[Reference]
The encoder pulse signal is used as the frequency
reference. When this function is selected, the frequency
reference selected in DRV-04 is ignored. Reference
Frequency versus Pulse Input Curve can be made by
four parameters of EXT -18 ~ EXT -21.
Code
LCD Display
EXT-12
F mode
EXT-15
F pulse set
EXT-17
F filter
EXT-18
F pulse x1
EXT-19
F freq y1
EXT-20
F pulse x2
EXT-21
F freq y2
Reference Frequency
EXT-21
EXT-19
EXT-18
[Reference Frequency vs. Pulse Input]
Setting in Feed back
Feed-back
A+B
360 ~ 4096
0 ~ 30000
0 ~ 30000
0 ~ 200[%]
10 ~ 500[%]
10 ~ 9999[mSec]
0 ~ 200[%]
0 ~ 200[%]
Setting in Reference
Reference
A
0 ~ 10000[msec]
0 ~ 10 [kHz]
0 ~ Max Freq [Hz]
0 ~ 10 [kHz ]
0 ~ Max Freq [Hz]
Pulse Input
(0 to 10 kHz)
EXT-20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents