Ext-13: Real Speed Direction - Sub-B; Ext-14: Encoder Feedback Frequency - Sub-B; Ext-15: Pulse Input Signal Selection - Sub-B; Ext-16: Encoder Pulse Number - Sub-B - LG SV-iS5 Instruction Manual

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

EXT-13: Real Speed Direction - Sub-B

EXT? RealSpdDir
13
RX
Factory Default:
Reverse
It displays actual motor rotation direction regardless of
control mode selected, when Sub-B board is installed
and EXT -12 is set to Feed-back.

EXT-14: Encoder Feedback Frequency - Sub-B

EXT? ENC FeedBac
14
0.00 Hz
Factory Default:
It displays frequency regardless of control mode
selected, when Sub-B board is installed and EXT -12 is
set to Feed-back.
EXT-15: Pulse Input Signal Selection – Sub-B
EXT? F pulse set
15
A + B
Factory Default:
A + B
This code sets the encoder pulse to use. [A+B] uses two
encoder signal lines of A and B, and [A] uses one
encoder signal line of A or B.
EXT-16: Encoder Pulse Number – Sub-B
EXT? F pulse num
16
1024
Factory Default:
1024
This code sets the encoder pulse per rotation of encoder.
EXT-17: Filtering Time Constant for Pulse Input
Signal – Sub-B
EXT?
F filter
17
10 ms
Factory Default:
10 ms
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
13
0
0
14
0.00
N/A
15
0
0
16
1024
1024
17
10
10
139
Chapter 6 - Parameter Description [EXT]
This is the filtering time constant of pulse input signal.
This is used to make the inverter respond slowly to the
pulse input signal when the EXT -14 is set to ' Reference' .
EXT-18 ~ EXT-21: Pulse Input Signal Adjustment
– Sub-B
This is used to adjust the pulse input signal when the
pulse input through Sub-B board references the
frequency. This function is applied when EXT -14 is set to
' Reference' . Reference Frequency versus Analog
Voltage Input Curve can be made by four parameters of
EXT -18 ~ EXT -21.
EXT? F pulse x1
18
0.0 kHz
Factory Default:
0.0 kHz
This is the minimum pulse frequency at which the
inverter outputs minimum frequency.
EXT?
F freq y1
19
0.00 Hz
Factory Default:
0.00 Hz
This is the minimum frequency the inverter outputs when
there is the minimum pulse frequency (EXT -18).
EXT? F pulse x2
20
10.0 kHz
Factory Default:
10.0 kHz
This is the maximum pulse frequency at which the
inverter outputs maximum frequency.
EXT?
F freq y2
21
60.00 Hz
Factory Default:
60.00 Hz
This is the maximum frequency the inverter outputs
when there is the maximum pulse frequency (EXT -20).
18
0.0
0.0
19
0.00
0.00
20
10.0
10.0
21
60.00
60.00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents