Operation Example - LG SV-iS5 Instruction Manual

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

Chapter 3 – Function Settings

3.2 Operation Example

Operation
V/F Control + Analog Voltage Input (V1) + Operation via Terminal (FX/RX)
Example (1)
[Operation condition]
-. Control mode: V/F control
-. Frequency command: 50[Hz] analog input via V1 terminal
-. Accel/Decel time: Accel – 15 [Sec], Decel – 25 [Sec]
-. Drive mode: Run/Stop via FX/RX terminal
[Wiring]
Step
Parameter setting
1
Control Mode Selection
2
Drive Mode
3
Frequency Mode
50[Hz] freq command
4
setting
5
Accel/Decel time
6
Terminal FX
7
Terminal RX
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
B1
R
3P
S
AC
input
T
G
S/W
FX
RX
BX
RST
JOG
P1
P2
P3
CM
Potentiometer
1[kohm],1/2W
VR
V1
5G
Code
FU2-39
Set it to 0 {V/F}.
DRV-3
Set it to Fx/Rx-1.
DRV-4
Set V1 Analog input value in frequency mode.
DRV-0
Set freq command 50[Hz] via V1 (potentiometer).
DRV-2
Set Accel time to 15 [Sec] in DRV-2.
DRV-3
Set Decel time to 25 [Sec] in DRV-3.
Motor starts to rotate in Forward direction at 50Hz with Accel time
15 [sec] when FX terminal is turned ON.
Motor decelerates to stop with Decel time 25[sec] when FX
terminal is turned OFF.
When RX terminal is turned ON motor starts to rotate in Reverse
direction at 50[Hz] with Accel time 15 [Hz]. When it is OFF, motor
decelerates to stop with Decel time 25 [Sec].
46
B2
U
IM
V
W
FM
5G
30A
30C
30B
AXA
AXC
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents