Restore KCU105 Si570 Frequency from EEPROM
Freq:200.0000000000 HS_DIV=7 N1=4 DCO=5600.0 RFREQ=0x030FFF204B
Restored Si570 Frequency = 200.000 from EEPROM
(The returned values include configuration setting details.)
Restore KCU105 Si5328 Frequency from EEPROM
Restoring Si5328 Frequency = 150.000 from EEPROM
Freq:150.0000000000 fosc=5400.000MHz f3=15.000KHz LBW=0.600KHz N1=36 N1_HS=6
NC1_LS=6 N2=360000 N2_HS=4 N2_LS=90000 N31=10000 N32=7619
(The returned values include configuration setting details.)
Return to Clock Menu
This option returns to the menu level above.
Option 5: View KCU105 Saved Clocks in EEPROM
This option is for verifying that the recently programmed values are in EEPROM.
Saved Clocks in EEPROM
-----------------------------
Si570 User Clock: 200.00000000 MHz
Si5328 MGT Clock: 150.00000000 MHz
Option 6: View KCU105 Clocks Restore Options
KCU105 System Controller
- Options Menu-
----------------------------------------------
1. View KCU105 Clock Restore Options
2. Enable KCU105 Si570 Automatic Restore at Power-Up Reset
3. Enable KCU105 Si5328 Automatic Restore at Power-Up Reset
4. Disable KCU105 Si570 Automatic Restore at Power-Up Reset
5. Disable KCU105 Si5328 Automatic Restore at Power-Up Reset
0. Return to Clock Menu
Select an option
View KCU105 Clock Restore Options
Clock Restore Options:
----------------------------------------------
Si570 Automatic Restore at Power-Up Reset = DISABLED
Si5328 Automatic Restore at Power-Up Reset = DISABLED
KCU105 Board User Guide
UG917 (v1.4) September 25, 2015
www.xilinx.com
Appendix C: System Controller