MSI-8000HD RF Remote Display
6.6
ScanList ID
The ScanList ID specifies the load cell/sensor that scale one through four will use for summing totals. It allows up to four
devices to be summed together on the remote display.
1. Press
and
F1
2. Press
to scroll to .
F2
3. Press
. displays.
F1
4. Press
. Current flashes.
F1
5. Set the ID number of the LC/Sensor that will be assigned to Scale.1
(0-3 are used to represent 1-4. For example, 0=1, 1=2, 2=3, 3=4).
6. Press
to store the number. displays.
F1
7. Press
. The scale ID must match the ID of the LC/Sensor being connected to.
F1
8. Press
to store the number. displays.
F1
9. Press
, The sensor number is used to select a LC connect to the Scale being addressed in .
F1
10. Press
to store the number. displays.
F1
11. Press
twice to exit to the weighing mode.
ZERO
The sum will now reflect the total of all LC/Sensors specified.
6.7
Zero and Tare in Multiple Load Cell Systems
The channel displayed is considered the Focus Channel. Pressing
When displaying summed channels, ZERO or TARE commands are sent to all devices that contribute to the displayed weight.
Example: If in the Both modes, and displaying pair 1 (sum of SC0 and SC1), pressing ZERO will zero only SC0
and SC1. If displaying the grand total using the ALL mode then pressing ZERO will zero all connected sensors.
32
Visit our website
at the same time. displays.
F3
PRINT
www.ricelake.com
or
only affects the displayed channel.
ZERO
TARE