Configuration; Quick Setup Menu - Rice Lake LaserLT-60 Technical Manual

Remote displays
Hide thumbs Also See for LaserLT-60:
Table of Contents

Advertisement

3.0

Configuration

This section provides an overview of LaserLT-60 and LaserLT-100 configuration.
3.1

Quick Setup Menu

Press
when the firmware version is displayed during power on to enter the Setup (Quick Setup) menu.
The Quick Setup menu contains options for remote display configuration.
Navigate configuration parameters by using the function keys, see
Use
and
to move across the menu and use
dSP.rF
PC SEL
PCModE
rEPE.6
Menu
Parameter
SEtUP
dSP.rF
(Setup)
SEriAL
inPutS
outPut
an.out
dEFAu
SEriAL
PC SEL
(Serial)
CoN.Prn
CoN.PC
CoM.PC
PCModE
(Communication PC)
baud
bit
Add.En
t.out
PCModE
rEPE.6
(PC Mode)
W.rEPE
Pr1577
rEPE.dC
rEPE.in
A.rEPE
F.modE
SEriAL
inPUtS
Com.PC
Com.Prn
bAUd
bit
PR1577
W.rEPE
Figure 3-1. Setup Navigation
Display Radio Frequency – Display refresh; Settings: norN, 1hz, 2.5 hz, 5 hz, 10 hz,, 20 hz
Serial – Access to serial port parameters
Inputs – Settings: inP.01, inP.02
Output – Settings: out.01, out.02
Annunciator Output – Settings: Capac, mode, Ao max, ao zer, ao min, Sign
Default – Resets each parameter to the default setting
PC Select – PC serial selection; Settings: 485, 232
Communication Print – Printer Serial
Communication PC – Port configuration for incoming data
PC Mode – Port setting for baud rate, bits, and time out
Baud – Common baud rate selection; Settings: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Bit – Set parity, word, and stop bit; Settings: n-8-1, e-7-2, e-7-1, n-7-2, n-8-2
Add.En – Settings: yes, no
Timeout – Sets the timeout communication; Select a value from 0.5–20; the default value is 1.5 seconds;
Maximum value is 20 seconds and the minimum value is 0.5 seconds
REPE.6 – Reception of the SCT 2200 string
U.REPE.6 – Configurable mode that allows identification and location of data in the string;
Default configuration for the Rice Lake continuous format by default
PR 1577 – Reception of the Pr1577 string
REPE.DC – Used when the indicator is connected to digital load cells while connected to the same network
REPE.In – Auto lean mode that allows reading of the received string automatically without setting any parameters
Auto.REPE – Alpha numeric mode that allows ASCII text to be displayed when a string is six characters followed
by <CR>
Table 3-1. Setup Parameter Definitions
Table 1-2 on page 3
for navigation assistance.
to move to the next level.
SEtUP
diAG
An.out
oUtPUt
t.oUt
rEPE.dC
rEPE.in
Description
© Rice Lake Weighing Systems ● All Rights Reserved
Configuration
dEFAU
A.rEPE
(Section 3.3 on page
7)
5