LaserLight3 Remote Display
8.8

Test Functions

8.8.1

Digital Output Test

The Digital Output Test displays if a digital output is operational.
Figure 8-17
displays a menu path to the Digout parameter.
1. Navigate to Setup ► Test ▼ Digout.
2. Press
. Bit 1 displays.
3. Press
or
4. Press
. The bit activates for three seconds, displays OK and then becomes inactive.
NOTE: Digital output bits must be configured as an output to be tested. "Bit not configured" displays if the test is activated
for a digital output bit that is not assigned. See
for digital I/O configuration description.
5. Press
to exit the menu.
8.8.2

Digital Input Test

Perform the following to test Digital Inputs:
The Digital Input Test Displays a summed decimal representation of all active Digital I/O (J5 on the CPU board) input signals.
Figure 8-17
displays a menu path to the Digin parameter.
1. Navigate to Setup ► Test ▼ Digout ►... ►Digin.
2. Press
. The summed values read from the digital input bits displays.
NOTE: The summed data range is 0 - 15. Each input bit provides a specific value:
3. Press
to exit the menu.
86
Visit our website
Setup
Mac ID
LightLvl
Figure 8-16. Digout parameter Menu Path
repeatedly until the desired Bit is selected.
Section 2.6.5 on page 18
Setup
Mac ID
LightLvl
Figure 8-17. Digin parameter Menu Path
Connector
Pin
J5
1
+5 VDC, 250 mA max
2
GND
3
DIO1
4
DIO2
5
DIO3
6
DIO4
Table 8-2. Digin Bit Range