How to interpret load or update charts from loaded CD-ROM window
1. The source and edition date of the CD is displayed here.
2. A list of charts stored in the CD-ROM, edition number of the chart and the number of updates included in the
chart.
3. In the Load Selectors field, you can select how to pick desired charts from the list:
• Name: ECDIS displays chart names on graphical presentation if selected.
• Permit: ECDIS highlights the charts that are available in the CD-ROM and for which you have permits.
• RENC Canceled Charts: ECDIS displays charts on display that are canceled on RENC and normally on
CD-ROM.
• Group: If you have predefined a group of charts, ECDIS will highlight those charts in the group that are
available in the CD-ROM.
• Manual selection: You can highlight desired charts from the list.
• Missing only: Loads and display on graphical presentation only charts and their updates that are not already
loaded into the ECDIS.
4. View CD-ROM Publisher Notes button: View important notices published by the chart producer.
View CD-ROM content Summary button: List charts available on CD-ROM.
Load and Conv. History button: Check what is loaded and converted from the CD-ROM.
Remove button: Remove the CD-ROM catalogue permanently from the ECDIS.
5. The Edit Group button is used to create and modify a group. See section 8.5.5 "How to group S57 chart cells".
6. The Load button starts loading.
8. Vector Chart Material
HDG
(MAN) 289.0°
SPD
(MAN)
SB
(MAN)
COG
(MAN) 289.0°
SOG
(MAN)
°
60
03.400'N
1.453 NM
+
°
°
024
58.372'E
352.0
0.0kn
kn
0.0kn
kn
1.
0.0kn
kn
2.
3.
4.
5.
6.
8-53