FE-700
IMPORTANT NOTICE ......................................................................................................i
Safety Instructions...............................................................................................ii
EQUIPMENT LISTS .......................................................................................................iii
System Configuration ..........................................................................................iv
1. MOUNTING .................................................................................................................1
1.1 Category of Equipment ........................................................................................................................... 1
1.2 Display Unit ............................................................................................................................................. 1
1.3 Transducer .............................................................................................................................................. 4
1.4 Distribution Box ....................................................................................................................................... 6
1.5 Matching Box .......................................................................................................................................... 7
1.6 Digital Depth Indicator FE-720 (option)................................................................................................... 7
1.7 Transducer Switch Box EX-8 (option) ..................................................................................................... 9
1.8 Gate Valve GV-50B-6B, GV-200B-8B (option)........................................................................................ 9
2. WIRING ..................................................................................................................... 11
3. CHANGING POWER SPECIFICATIONS ..................................................................20
4. ADJUSTMENTS ........................................................................................................22
4.1 Transducer Setting ................................................................................................................................ 22
4.2 Setting the Time .................................................................................................................................... 24
Packing ListS......................................................... ...................................A-1
Outline DrawingS................................................... .................................D-1
Interconnection Diagrams................................. ................... ................S-1
www.furuno.co.jp
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FE-700 and is the answer not in the manual?

Questions and answers

Sean McNulty
March 10, 2025

When installing the transducer is it required to face a certain way?

1 comments:
Mr. Anderson
March 10, 2025

Yes, the Furuno FE-700 transducer should be installed properly to ensure accurate readings. It is recommended to install the transducer on the keel line or between 600 mm and 900 mm from the keel to minimize the effect of aerated water. The installation location should avoid obstructions such as the forward propeller, bow thruster, water intake pipes, and speed log sensor. Additionally, the transducer tank should be flush with the hull bottom.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Furuno FE-700

  • Page 1 Installation Manual NAVIGATIONAL ECHO SOUNDER FE-700 IMPORTANT NOTICE ...i SAFETY INSTRUCTIONS...ii EQUIPMENT LISTS ...iii SYSTEM CONFIGURATION ...iv 1. MOUNTING ...1 1.1 Category of Equipment ... 1 1.2 Display Unit ... 1 1.3 Transducer ... 4 1.4 Distribution Box ... 6 1.5 Matching Box ...
  • Page 2 Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 : +81-(0)798-65-4200 All rights reserved. Printed in Japan Pub. No. IME-23660-Q (DAMI ) FE-700 The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer A : JAN Q : JUL . 24, 2009...
  • Page 3 The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation. Be sure that the power supply is compatible with the voltage rating of the equipment.
  • Page 4: Equipment Lists

    Standard Supply Name Type Display Unit FE-701 Distribution Box FE-702 MB-502 Matching Box MB-504 50B-6B Transducer 200B-8B TTF-5600 Transducer Tank TTF-2000 Spare Parts SP02-04101 Installation Materials CP02-06301 Optional Supply Name Type Transducer Switch EX-8 Cable Assy. FM-C6FPS003- JUNCTION Box JIS F8821-1MO 0-20A3P TTF-5001 TTF-2001...
  • Page 5 Name MF-22L-1-100V MF-22L-1-200V Dimmer MF-22L-2-100V MF-22L-2-200V Terminal Box DS-802 EGC Printer PP-505-FE GV-50B-6B Gate Valve GV-200B-8B Alarm Unit AU-12 Distribution Box MB-1200 Type Code no. 000-069-401 000-069-403 000-069-402 000-069-404 000-029-064 000-055-892 000-015-265 000-015-273 000-016-185 Remarks 100 VAC-120 VAC, Flush mount type 200 VAC-240 VAC, Flush mount type 100 VAC-120 VAC,...
  • Page 6: System Configuration

    DISTRIBUTION BOX FE-702 DISTRIBUTION SWITCH BOX EX-8 MB-1200 SYSTEM CONFIGURATION DISPLAY UNIT FE-701 Contact signal JUNCTION BOX JISF8821-1M0 0-20A3P Matching Box MB-502 (For 50B-6B) MB-504 (For 200B-8B) TRANSDUCER 50B-6B, 200B-8B Terminal Box DS-802 IEC 61162-1 DIGITAL DEPTH INDICATOR FE-720 IEC 61162-1 Navigation Device IEC 61162-1 Navigation Device...
  • Page 7: Mounting

    Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 Category of Equipment Equipment for protected area •...
  • Page 8 • Mount the unit where shock and vibration are minimal. • Keep the unit away from electromagnetic field-generating equipment such as motors and generators. • For maintenance and checking purposes, leave sufficient space at the sides and rear of the unit and leave slack in cables.
  • Page 9 Dummy cover 5x20 tapping screws 1.2.4 Flush mounting There are two types of flush mount kits, F type and S type. For details, see the outline diagrams at the back of this manual.
  • Page 10: Transducer

    F type Flush Mount Kit (F): OP02-79-1 (001-229-290) OP02-79-2 (001-229-300) OP02-79-3 (001-229-310) Name Type Cosmetic 02-129-1041-0 panel Hex bolt M6x12 Spring washer 1. Prepare a cutout in the mounting location whose dimensions are 210 (W) x 194 (H) mm. 2. Attach the cosmetic panel (02-129-1041-0) to the display unit with four hex bolts (M6x12) and four spring washers (M6).
  • Page 11: Mounting Location

    1.3.1 Mounting Location To decide the location of the transducer, the following points should be taken into account. • The most important matter is where the transducer is installed. The position should be free from aeration possibly occurring beneath the hull and also not affected by engine and propeller noise.
  • Page 12: Distribution Box

    7. It is recommended to enclose the transducer cable in a conduit pipe for waterproofness and electrical shielding as well as for protecting the cable from mechanical damage. The conduit pipe should be fixed to the flange on the transducer tank. The pipe should be of such a length to clear the water level when the ship is fully loaded.
  • Page 13: Matching Box

    1.5 Matching Box The matching box should be selected depending on the transducer type; • 50B-6B transducer: MB-502 • 200B-8B transducer: MB-504 Fasten the matching box with four Trapping screws (6x20: local supply). Compass safe distances are as follows; standard compass: 0.50 m, Steering compass: 0.40 m. 1.6 Digital Depth Indicator FE-720 (option) The indicator can be installed on a tabletop, on the overhead.
  • Page 14 F type Use the accessories FP65-00401 (See page A-7). 1. Prepare a cutout in the mounting location whose dimensions are 183 (W) x 92 (H) mm. 2. Attach the cosmetic panel (20-016-1051) to the indicator with two hex bolts (M6x12) and two spring washers (M6).
  • Page 15: Transducer Switch Box Ex-8 (Option)

    1.7 Transducer Switch Box EX-8 (option) If two transducers are installed, the transducers switch box is required. Locate the transducer switch box near the display unit considering length of the interconnection cable. Select the bright place where the panel of equipment can be watched. Use only the screws supplied on the terminal inside to make connections.
  • Page 16 4. Grease (supplied) both sides of the gasket 1 and the inner side of the spacer. Place the gasket 1 onto the spacer. 5. Clean the flange side of the gate valve, and place it on the gasket 1. The scale side of the gate valve should be up.
  • Page 17: Wiring

    Wiring Connect three cable assemblies (supplied) between the display unit and distribution box. See the interconnection diagram for details. Display unit FE-701 (rear panel) MJ-A3SPF0015-100C Personal computer MJ-A10SPF0002-100 (EIA-232C) DPYCYS-1.5 Ship's mains Alarm system TB5 DC 12345678910 Ship's Alarm Main System 61162-1 TPYCYS-1.5...
  • Page 18 When the Transducer Switch Box EX-8 or Distribution Box MB-1200 is used, the interconnections are as follows. Display unit FE-701 (rear panel) MJ-A3SPF0015-100C Personal computer (EIA-232C) MJ-A10SPF0002-100 DPYCYS-1.5 Ship's mains Alarm system CONE board 02P6283 TB5 DC 12345678910 Ship's Alarm Main System 61162-1...
  • Page 19 Cable Fabrication of DPYCYS-2.5, DPYCYS-1.5, MJ-A3SPF0015-100C , FM-C6FPS0002-100 and TPYCYS-1.5 Fabricate the power and other cables as illustrated below to connect them to the Distribution box. Vinyl Sheath Armor Vinyl Sheath *: Depending on cables, fabrications are as follows. DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Others Vinyl Sheath Shield...
  • Page 20 Several cables are required to supply at local. In this manual, JIS (Japan Industrial Standard ) cables are specified. Use equipment cables refering to the figures below. Shield Sheath Shield Sheath Armor Armor Core Core S=1.5 mm S=2.5 mm =1.56mm Vinyl sheath =2.01mm Vinyl sheath...
  • Page 21 Cable Fabrication of TTYCYS-4 TTYCYS is a Japan Industrial Standard (JIS) cable. Use the equipment one. Vinyl Sheath Armor Vinyl Sheath Vinyl Sheath Shield 50mm 40mm Armor 100mm Fold back shield over on vinyl sheath. Shield Taping Vinyl Tape Shield Clamp here.
  • Page 22 2 Rotate Special tool for connecting wires, fitted inside the Distribution Box Insert Terminal Board TB1, TB3 Cross section Power Supply Cable from Ship's Mains If the ship's mains is AC, the power supply cable must be connected to TB5 in the Distribution Box.
  • Page 23 Transducer Connect the transducer cable to the distribution box. If necessary, attach the junction box between the distribution box and matching box. Ground Connect the ground wire (2.0 sq.) from both the display unit and distribution box to ship’s ground to prevent interference to the picture. Shorten the ground wire as much as possible. The optional digital depth indicator FE-720 should be grounded by 1.25 sq.
  • Page 24 Alarm system connection The power error and shallow water alarms, which produce audio and visual alarms in the event of power failure and shallow water, can be output by connecting the distribution box to the ship’s alarm system. Connect the DPYCYS-1.5 cable between TB1 in the Distribution Box and the alarm system of the ship referring to the schematic diagram at the end of this manual.
  • Page 25 Case2: Silencing the alarm from the digital depth indicator FE-720 When the main display unit FE-701 activates an alarm, it can be deactivated at the FE-701 itself and also, it can be deactivated from the digital depth indicator FE-720. To do this, connect as follows.
  • Page 26: Specifications

    This unit is set at factory to operate from 220-230 VAC ship's mains. For connection to a 100 VAC, 110-115 VAC, 200 VAC or 24 VDC ship's mains, modify the connections in the distribution box as shown below. Note: Tick the appropriate box on the inside of the FE-702 distribution box cover to denote the power use.
  • Page 27 24 VDC Ship's Mains Remove the cover of the distribution box. Remove P3 connector from J4 on the CONE Board. Reattach P3 connector to J3 on the CONE Board. Connect the power cable to TB6. For DC ship's mains For AC ship's mains Distribution box, inside view CONE Board...
  • Page 28: Adjustments

    3. Set the transducer(s) as shown below. Use [▲] or [▼] to select an item and [+] or [-] to set option. a) CHANGEOVER sets how transducer(s) is connected to the FE-700. Select MANUAL for single transducer or transducers connected via Switch Box EX-8. Select AUTO for connection via Distribution Box MB-1200.
  • Page 29 Note: If CHANGEOVER is set for MANUAL, select SINGLE. 49.6 BELOW SURFACE SINGLE: Single frequency DISP ORDER sets where to locate the fore and aft displays (right or left side) in the dual frequency display. g) OUTPUT sets what data to output to external equipment (in IEC/NMEA data format) in case of dual frequencies.
  • Page 30: Setting The Time

    Setting the Time Open the system menu 2 referring to the operator’s manual. MENU SELECT TIME ADJUST MONTH YEAR HOUR MINUTE SECOND 01 JAN 2009 : To select item - +: To set option Select other mode to exit. System menu 2 Press [▼] key to select TIME ADJUST.
  • Page 40 D-3a...
  • Page 50 D-13 Y. Hatai...
  • Page 51 D-14 Y. Hatai...
  • Page 52 D-15 Y. Hatai...
  • Page 53 D-16 Takahashi.T...
  • Page 54 D-17 Y. Hatai...
  • Page 55 D-18 Y. Hatai...
  • Page 56 D-19 T.MAtsuguchi Apr.28'06...
  • Page 57 D-20 T.Matsuguchi Apr.28'06...
  • Page 58: Interconnection Diagrams

    MB-1200 5 2 1 IV-2sq. IV-2sq. DPYCYS-2.5 *1 接続箱 接続箱 DPYCYS-2.5 *1 整合箱 MATCHING BOX MB-502(50B-6B) MB-504(200B-8B) 2RNCT-SB 2Cx1.4 15/30/50m,φ11.8 50B-6B 50B-6B 200B-8B 200B-8B 送受波器 TRANSDUCER TITLE FE-700 T.YAMASAKI 名称 音響測深機 T.TAKENO 相互結線図 MASS NAME NAVIGATIONAL ECHO SOUNDER INTERCONNECTION DIAGRAM...