1. Introduction
1.2

System Configuration

The ECDIS EC1000C Workstation, comprised of the components shown in the illustration below, displays
electronic sea charts and operates as the user interface for the system.
The ECDIS processor is connected to various sensors, and performs navigation calculations and route monitoring.
Connections to interfaces are typically made with a LAN (Local Area Network) Adapter.
The ECDIS processor can be used for both route planning and route monitoring. If required, there can be additional
identical ECDIS EC1000C Workstation(s) connected to the same LAN to share the tasks of the ECDIS. If the
system incorporates more than one ECDIS EC1000C Workstation, one or more workstation(s) can be used as an
user interface (with "full" usage rights) and one or more workstation(s) may be used as planning stations (usage
rights as "planning").
If the system has two workstations connected together as multiple workstations, the system keeps data on the
workstations harmonised and also tracks selections and settings made on any workstation.
Typically there can be the following kinds of configurations of workstations:
Mode as Single, only one workstation is used in the system.
Mode as Multiple, two workstations are used in the system, and usage rights and sensor source of workstations
can be changed by the operator.
1.2.1

Single workstation

MONITOR UNIT
MU-201CE (FEA-2107)
100-230 VAC
MU-190 (FEA-2107)
MU-231CE (FEA-2807)
MU-231 (FEA-2807)
CALCOMP
DRAWING-
BOARD III
DIGITIZER
(WORKSTATION)
ECDIS PROCESSOR
RADAR OVERLAY PCB
100-230 VAC
FAR-2xx7
series radar
CONTROL UNIT
CONTROL UNIT
REMOTE CONTROL
Category of Units: All units protected from weather
1-2
* Conning use
MONITOR UNIT*
MU-201CE (FEA-2107)
MU-190 (FEA-2107)
MU-231CE (FEA-2807)
MU-231 (FEA-2807)
HUB-
100
100-230 VAC
EC1000C
RCU-018
or
RCU-015
UNIT
RCU-016
Single workstation with connection to navigation sensors
100-230
VAC
LAN-ADAPTER
EC-1010
24 VDC
LAN-ADAPTER
EC-1010
24 VDC
B-ADAPTER
EC-1020
24 VDC
Selector
PRINTER
(USB)
TT RADARS
NAVTEX
TRACKPILOT
LOG/DUAL AXIS LOG
AIS
GYROCOMPASS
NAVTEX
ENGINE CONTROL
ECHOSOUNDER
WIND SENSOR
WATER TEMP. METER
AMWSS (Alarm Monitoring
Watch Safety System)
GYROCOMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNELS)
ALARM OUTPUT
RADAR 1 (VIDEO, HL, AZ)
RADAR 2 (VIDEO, HL, AZ)
OPTION
EXTERNAL
DEVICE