Furuno FELCOM18 Installation Manual

Furuno FELCOM18 Installation Manual

Inmarsat-c mes
Hide thumbs Also See for FELCOM18:

Advertisement

Installation Manual
INMARSAT-C MES
FELCOM18
Model
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATION ........................................................................................... ii
EQUIPMENT LISTS........................................................................................................ iii
1. MOUNTING..............................................................................................................1-1
1.1 Antenna Unit ......................................................................................................................1-1
1.2 Terminal Unit......................................................................................................................1-2
1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306..............................................1-5
1.4 Printer (option) ...................................................................................................................1-6
1.5 AC/DC Power Supply Unit PR-240 (option).......................................................................1-7
1.6 Junction Box IC-318...........................................................................................................1-8
2. WIRING....................................................................................................................2-1
2.1 Antenna Cable Connector at the Terminal Unit .................................................................2-2
2.2 Distress Alert/Received Call Unit IC-305 ...........................................................................2-5
2.3 Alarm Unit IC-306 ..............................................................................................................2-5
2.4 Junction Box IC-318...........................................................................................................2-6
3. INITIAL SETTINGS..................................................................................................3-1
3.1 How to Set the IMN (INMARSAT MOBILE NO.)................................................................3-1
3.2 How to Set External Equipment .........................................................................................3-2
3.3 How to Set the Alarm Contact............................................................................................3-3
3.4 How to Set up the AMS......................................................................................................3-3
3.5 How to Select Position-fixing Equipment ...........................................................................3-5
3.6 How to Set up for 2nd DTE ................................................................................................3-5
4. HOW TO INSTALL OPTIONAL EQUIPMENT ........................................................4-1
4.1 GPS Board OP16-62 .........................................................................................................4-1
4.2 IPX2 Kit OP16-58/OP16-59 ...............................................................................................4-2
4.3 Waterproofing Kit OP16-60/OP16-67/OP16-68 .................................................................4-7
5. HOW TO CHANGE POWER SUPPLY SPECIFICATIONS.....................................5-1
APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1
PACKING LISTS ......................................................................................................... A-1
OUTLINE DRAWING ................................................................................................... D-1
INTERCONNECTION DIAGRAM ................................................................................ S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FELCOM18 and is the answer not in the manual?

Questions and answers

Summary of Contents for Furuno FELCOM18

  • Page 1: Table Of Contents

    Installation Manual INMARSAT-C MES FELCOM18 Model SAFETY INSTRUCTIONS ....................i SYSTEM CONFIGURATION ................... ii EQUIPMENT LISTS......................iii 1. MOUNTING......................1-1 1.1 Antenna Unit ........................1-1 1.2 Terminal Unit........................1-2 1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306..........1-5 1.4 Printer (option) ........................1-6 1.5 AC/DC Power Supply Unit PR-240 (option)...............1-7 1.6 Junction Box IC-318......................1-8...
  • Page 2 ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN A : JUN 2012 Printed in Japan All rights reserved. C : JUN . 10, 2013 Pub. No. IME-56740-C ( AKMU ) FELCOM18 0 0 0 1 7 6 5 1 9 1 2...
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS CAUTION WARNING Do not open the equipment Confirm that the power supply unless totally familiar with voltage is compatible with the electrical circuits and voltage rating of the equipment. service manual. Connection to the wrong power Only qualified personnel ELECTRICAL supply can cause fire or equipment should work inside the...
  • Page 4: System Configuration

    SYSTEM CONFIGURATION Standard configuration is shown with solid line. ANTENNA UNIT IC-118 DGPS TERMINAL UNIT POWER SUPPLY IC-218 100-115/200-230 VAC , AC/DC Power Supply 1φ 50/60 Hz PR-240 POWER SUPPLY 24 VDC Built in POWER SUPPLY GPS Board Shipboard LAN (Ethernet) 12/24 VDC OP16-62 Printer**...
  • Page 5: Equipment Lists

    EQUIPMENT LISTS Standard supply Name Type Code No. Remarks Antenna Unit IC-118 w/FP16-02501 Terminal Unit IC-218 w/CP16-05200, SP16-01301, FP16-02600 Junction Box IC-318 SSAS Alert Unit IC-307 For SSAS only Installation CP16-05500 000-021-697 For IC-118, 30 m Materials Optional supply Name Type Code No.
  • Page 6 EQUIPMENT LISTS Name Type Code No. Remarks Installation Materials CP16-05710 000-021-701 w/pipe, 30 m CP16-05750 000-021-704 w/o pipe, 30 m CP16-05780 000-021-712 w/pipe, 30 m, for armored cable CP16-05790 000-021-715 w/o pipe, 30 m, for armored cable CP16-05720 000-021-708 w/pipe, 40/50 m for armored cable w/o pipe, 40/50 m, CP16-05760...
  • Page 7: Mounting

    MOUNTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. Antenna Unit 1.1.1 Mounting location Refer to IMO resolutions A663(16) and A.807(19), as amended. •...
  • Page 8: Terminal Unit

    1. MOUNTING • Separate the antenna unit from an S-band radar as follows: Install above this line INSTALLTION ZONE PROHIBITED ZONE 1.5 m S-band radar HORIZONTAL LINE • The allowable vibration level as specified by Inmarsat is as shown in the table be- low.
  • Page 9 1. MOUNTING Mounting Tabletop mount 1) Fix the hanger (option) to a table with four self-tapping screws (5x20, supplied), re- ferring to the outline drawing at the back of this manual. 2) Screw knobs and washers to terminal unit loosely. 3) Set the terminal unit to the hanger and tighten knobs.
  • Page 10 1. MOUNTING How to connect the LAN cable Connect the LAN cable using the sponge and LAN cable support (supplied). This pro- cedure should be done even if the LAN cable is not used, to waterproof the unit. 1. Attach the sponge for LAN terminal to the LAN terminal. Sponge for LAN terminal 2.
  • Page 11: Distress Alert/Received Call Unit Ic-305/Alarm Unit Ic-306

    1. MOUNTING Keyboard 1. Attach the function key label (IMN-C ) to the keyboard as shown below. 2. Attach four fasteners (small, supplied) to the bottom of the keyboard. 3. Attach four fasteners (large, supplied) to the small fasteners attached at step 2. 4.
  • Page 12: Printer (Option)

    1. MOUNTING 3) Refasten two screws removed at step 1) to fix the clamp. Unfasten these screws. Refasten screws. Rotate. 4) Run the interconnection cable thorough a cable entrance and connect it to ter- minal board. Flush mount The optional flush mounting kit OP16-27 (Code No.: 004-448-000) is required. Name Type Code No.
  • Page 13: Ac/Dc Power Supply Unit Pr-240 (Option)

    1. MOUNTING AC/DC Power Supply Unit PR-240 (option) Fix the unit on a table with four self-tapping screws. AC/DC power supply unit PR-240...
  • Page 14: Junction Box Ic-318

    1. MOUNTING Junction Box IC-318 The junction box IC-318 is connected to the terminal unit by using the cable assy 16S0344 (2 m, attached to the junction box). Install the junction box within 2 m from the terminal unit. 1. Remove four screws from the unit to separate the bottom chassis from the top chassis.
  • Page 15: Wiring

    WIRING 24 VDC VCTF-0.75x3C (5 m) For cable w/armor 0.34 m Cable Assy. Printer TPA5FB0.4NJ5FBA-5DFB Ground wire PP-510/PP-520 5D-FB-CV-NP, 30 m TP5FBAW-5DFB,30 m (No armor) 8D-FB-CV, 50 m 16S0184, 3 m Connector at both 12D-SFA-CV, 100 m ends Connector at one end TNCP-NJ DGPS connector...
  • Page 16: Antenna Cable Connector At The Terminal Unit

    2. WIRING Antenna Cable Connector at the Terminal Unit 5D-FB-CV-NP (30 m) Outer Sheath Inner Sheath Braided Shield Armor Remove the outer sheath, armor and inner- sheath by the dimensions shown. Set the nut, washer, gasket, clamp onto Cover with heat-shrink tubing and heat. cable as shown.
  • Page 17 2. WIRING 8D-FB-CV (50 m) Dimensions in millimeters. Outer Sheath Remove outer sheath and armor by the Inner Sheath Armor Shield dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Cover with heat-shrink tubing and heat. Remove insulator and core by 10 mm.
  • Page 18 2. WIRING 12D-SFA-LITE-CV (100 m) Dimensions in millimeters. Outer Sheath Armor Inner Sheath Shield Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Cover with heat-shrink tubing and heat. Twist shield end.
  • Page 19: Distress Alert/Received Call Unit Ic-305

    2. WIRING Distress Alert/Received Call Unit IC-305 Use the installation materials CP16-02201 to connect the IC-305. The optional CO- SPEVV-SB-C 0.2x5P cable or JIS cable (Japan Industrial Standard) TTYCS(LA)-4 or equivalent are available to connect with the junction box IC-305. Select the cable clamp attached according to the diameter of cable, and fix the armor of the cable with the clamp.
  • Page 20: Junction Box Ic-318

    2. WIRING Junction Box IC-318 Use the junction box IC-318 to connect the distress alert/received call unit IC-305 and other units (max. four units) to the terminal unit. Unfasten four screws to remove the units cover to connect cables. For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable (Ja- pan Industrial Standard) TTYCS(LA)-4 or equivalent.
  • Page 21: Initial Settings

    INITIAL SETTINGS This chapter shows you how to setup the equipment. Some procedures require entry of job no. and password. Ask your dealer. How to Set the IMN (INMARSAT MOBILE NO.) Set your IMN (Inmarsat Mobile No.) as shown below. 1.
  • Page 22: How To Set External Equipment

    3. INITIAL SETTINGS How to Set External Equipment The FELCOM 18 is set at the factory to accept the distress alert/received call unit IC- 305, up to three alarm units IC-306 and the SSAS alert unit IC-307. If the configuration is different, change the setting to OFF as below.
  • Page 23: How To Set The Alarm Contact

    3. INITIAL SETTINGS How to Set the Alarm Contact 1. Press the F8 and 1 keys to show the [System Setup] menu. 2. Press ↓ to select [Command Window], and then press the Enter key. 3. Enter the [Enter JOB No.:], then press the Enter key. 4.
  • Page 24 [Distress Alarm Stop Disable]: The AMS can not stop the alarm sound when the Distress Priority message is received. 2 key: [MY SFI Setup] Command Window Set the SFI of FELCOM18. Enter the four- MY SFI Setup digit number that follows “CS”. CS0001 0000 to 9998: SFI No.
  • Page 25: How To Select Position-Fixing Equipment

    3. INITIAL SETTINGS How to Select Position-fixing Equipment Select the position-fixing equipment that is to feed navigation data to the FELCOM. 1. Press the F8 and 1 keys to show the [System Setup] menu. 2. Select [NAV Port] then press the Enter key. 3.
  • Page 26 3. INITIAL SETTINGS This page is intentionally left blank.
  • Page 27: How To Install Optional Equipment

    HOW TO INSTALL OPTIONAL EQUIPMENT GPS Board OP16-62 This chapter provides the procedure for the installation of the GPS board (in the ter- minal unit), which provides GPS position information. Name: GPS board Type: OP16-62 Code No.: 001-180-100 Name Type Code No.
  • Page 28: Ipx2 Kit Op16-58/Op16-59

    4. HOW TO INSTALL OPTIONAL EQUIPMENT 3. Attach the 51065-0700-PHR7-L110 connector assy. between J13 on the TERM- CPU Board and J1 on the GPS board. Binding screw M3x6, 3 pcs. GPS board 4. Attach the cable from the GPS board to J6 on the RF COMMCPU Board. Use the clamp next to the connector to fix the cable.
  • Page 29 4. HOW TO INSTALL OPTIONAL EQUIPMENT 4.2.2 OP16-59 (for connector ports) OP16-59 (001-180-080) Name Type Code No. Sponge for Dsub 16-023-3531 100-369-600-10 Cover for BNC 16-023-3534 100-369-630-10 Cover for USB 16-023-3535 100-369-641-10 USB Support 16-023-3536 100-369-650-10 Sponge for BNCR 16-023-3541 100-369-690-10 Dummy Plate 9P 16-023-3542...
  • Page 30 4. HOW TO INSTALL OPTIONAL EQUIPMENT D-sub ports Peel the paper from the sponge for Dsub (16-023- 3531), then attach the sponge to the D-sub connectors at the rear of the terminal unit. Sponge for Dsub Sponge for Dsub (Cables connected) Connect the cables supplied with OP16-58 to the appro- priate ports.
  • Page 31 4. HOW TO INSTALL OPTIONAL EQUIPMENT DGPS port (Coaxial cable connected) Pass the coaxial cable through the slit on the cover for BNC (16-023-3534). Cover for BNC Cover for BNC Attach the connector* of the coaxial cable to the DGPS port.
  • Page 32 4. HOW TO INSTALL OPTIONAL EQUIPMENT (Coaxial cable not connected) Sponge for BNCR Sponge for BNCR Remove the cap from the DGPS port, then atttach the sponge for BNCR (16-023- 3541) around the port. Re-attach the cap to the DGPS port.
  • Page 33: Waterproofing Kit Op16-60/Op16-67/Op16-68

    4. HOW TO INSTALL OPTIONAL EQUIPMENT Waterproofing Kit OP16-60/OP16-67/OP16-68 To mount the IC-318, IC-305 and IC-307 on a bulkhead, use the optional waterproof- ing kit to keep water splash out of the unit OP16-60 (for IC-318) OP16-60 (Code No.: 001-180-090) Name Type Code No.
  • Page 34 4. HOW TO INSTALL OPTIONAL EQUIPMENT OP16-67 (for IC-305), OP16-68 (for IC-307) Note: These kits cannot be used if the IC-305/IC-307 is mounted face upward. OP16-67 (Code No.: 001-189-380) Name Type Code No. Fixing Tape 24-009-1225 100-366-200-10 OP16-68 (Code No.: 001-189-400) Name Type Code No.
  • Page 35: How To Change Power Supply Specifications

    HOW TO CHANGE POWER SUP- PLY SPECIFICATIONS The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s mains. If the ship’ mains is 100 VAC, change the tap connection and terminal board connection as below. Attach a label supplied as accessories to the front panel according to the ship’s mains.
  • Page 36 5. HOW TO CHANGE POWER SUPPLY SPECIFICATIONS This page is intentionally left blank.
  • Page 37: Appendix 1 Jis Cable Guide

    EX: TTYCYSLA - 4 MPYC - 4 TTYCSLA-4 Core Area (mm # of cores Designation type Designation type The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Cable Core Core Cable Diameter Diameter...
  • Page 47 Y.NISHIYAMA 17/May/2012...
  • Page 48 Y.NISHIYAMA 30/Apr/2012...
  • Page 49 Y.NISHIYAMA 30/Apr/2012...
  • Page 52 Y.NISHIYAMA 17/May/2012...
  • Page 53 July 14'03...
  • Page 55 Dec. 20, '02...
  • Page 56 D-10...
  • Page 57 D-11 Y. NISHIYAMA 6/Oct/2010...
  • Page 58 D-12...
  • Page 59 D-13...
  • Page 60 D-14...
  • Page 61 D-15 Y.NISHIYAMA 31/May/2012...
  • Page 62: Interconnection Diagram

    アラームユニット ALARM UNIT IC-306 TD/RD-A TD/RD-B アンテナユニット ANTENNA UNIT IC-118 ターミナルユニット IC-350を接続するとき(IC-305との共用不可) 接続箱 TERMINAL UNIT 遭難警報器 CONNECTION FOR IC-350 (DO NOT USE W/ IC-305) JUNCTION BOX TPA5FB0.4NJ5 IC-218 DISTRESS ALERT/ 12D-SFA-CV,100m,φ20: N-P-12DSFA JUNCTION 17JE-23150 FBA-5DFB,0.4m IC-318 RECEIVED CALL UNIT 8D-FB-CV,40/50m,φ14.3: N-P-8DFB -02(D8C) IC-305 5D-FB-CV,30m,φ10.7: N-P-5DFB...

Table of Contents

Save PDF