IPNext 190 System Installation Guide
Utilization
To configure the settings for checking the possible usage of CPU or a particular interface in a certain time interval,
use utilization command. 1 minute is set at the default.
Use show utilization command to check the system usage by each Maximum, Minimum, Average, Last 30 seconds.
Step
1
IP-PBX#
IP-PBX# configure terminal
IP-PBX(config)#
2
IP-PBX(config)# utilization ?
fastethernet
CPU
3
IP-PBX(config)# utilization fastethernet
4
IP-PBX(config)# utilization cpu
5
IP-PBX# clear utilization
Step
1
IP-PBX# show run
Building configuration...
Current configuration:
version 8.47.024
hostname IP-PBX
!
utilization cpu
utilization FastEthernet
2
IP-PBX # show utilization
CPU utilization : enabled, Period : 30 seconds
last 30 seconds : 11 %
maximum:12%, time: Sun Jan 4 11:02:15 1970
Table 3-19 Utilization Configuration Settings
Command
FastEthernet IEEE 802.3
CPU usage
Table 3-20 Verifying Utilization Settings
Command
AddPac Technology Proprietary & Documentation
Description
Enter APOS command mode
Set utilization
(Default: disable)
Choose the option for utilization Apply
FastEthernet: Interface Utilization
Apply CPU Utilization
Enable FastEthernet Utilization
Enable CPU Utilization
Initialize the information of utilization
collected in the IP-PBX
Description
Use show rung command to
verify utilization settings
Use show utilization command
to
verify
the
information
of
CPU
interface.
utilization
and
132 - 54