Executing From External (Through Ethernet Connection) - Siemens SINUMERIK 808D ADVANCED Programming And Operating Manual

Computer numeric control
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Note
After you properly configure all the settings for the direct connection between the control system and the network drive, if the
network drive connection is still invalid, contact your Windows system administrator for possible problems with your
operating system configuration.
6.5.2

Executing from external (through Ethernet connection)

Prerequisites:
● An Ethernet connection has been established between the control system and the PC.
● A network drive (which includes the part program to be executed) has been created and connected.
Proceed as follows to execute a part program from external through the Ethernet connection:
46
6.
Move the cursor to the following input fields:
: Enter the user name of your Windows account
: Enter the logon password (case sensitive) of your Windows account
: Enter the IP address of the server and the share name of the shared directory on your
PC. Example: //140.231.196.90/808D
7.
Press this softkey to confirm and the configured network drive appears on the screen as
follows. The drive icon is yellow if the network drive is connected successfully; otherwise,
the icon is gray.
You can delete a selected network drive using this softkey.
1.
Select the desired operating area on the PPU.
2.
Press this softkey to view the network drive(s) created.
3.
Enter the desired network drive (which includes the part program to be executed) with this
key.
4.
Select the program file you desire to execute.
Programming and Operating Manual (Turning)