Circular Interpolation Via Intermediate Point: Cip - Siemens SINUMERIK 808D ADVANCED Programming And Operating Manual

Computer numeric control
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Programming example: Definition of end point and aperture angle
N5 G90 Z30 X40
N10 G2 Z50 X40 AR=105
Programming example: Definition of center point and aperture angle
N5 G90 Z30 X40
N10 G2 K10 I-7 AR=105
Note
Center point values refer to the circle starting point!
8.4.2

Circular interpolation via intermediate point: CIP

Functionality
The direction of the circle results here from the position of the intermediate point (between starting and end points).
Specification of intermediate point: I1=... for the X axis, K1=... for the Z axis.
CIP remains active until canceled by another instruction from this G group (G0, G1...).
The configured dimensional data G90 or G91 applies to the end point and the intermediate point.
74
; Starting point circle for N10
; Opening angle and end point
; Starting point circle for N10
; Opening angle and center point
Programming and Operating Manual (Turning)
6FC5398-5DP10-0BA2, 06/2015