Otherwise: Enabling ports via the service shell

Note
The port enable procedure applies only to the following SINUMERIK control:
● SINUMERIK 840D sl
Operating sequence
1. Open a service shell on the TCU.
2. Enter the command "sc openport tcp/22 <IP Address>".
3. This command opens port 22 in the firewall on the workplace network (X130) for a default
time of 15 minutes. The default time can be adjusted via the option -MINUTES. The
maximum possible time is 60 minutes.
If necessary you can repeat the command for port 5900.
5.2.2

Assigning parameters for direct connection (peer-to-peer Ethernet)

Requirement
● You are connected to the X127 interface of the control by an Ethernet cable.
Note
The SINUMERIK 808 control uses the X130 interface instead of the X127 interface for a
direct connection. Follow the corresponding control manuals when assigning parameters.
● The SSH port 22 in the firewall to the company network is enabled (Page 22).
SINUMERIK Integrate Access MyMachine /P2P (PC)
Operating Manual, 11/2016, A5E39356962B AA
Connection to the control
5.2 Assigning the connection parameters
25