Command
:MEASure[:NORMal]:ITEM:{TIME|MATH} Sets/queries the ON/OFF state of the communication output of
:MEASure[:NORMal]:ITEM:<normal measurement function>?
:MEASure[:NORMal]:ITEM:<normal measurement function>[:ALL]
:MEASure[:NORMal]:ITEM:<normal measurement function>:ELEMent<x>
:MEASure[:NORMal]:ITEM:<normal measurement function>:SIGMa
:MEASure[:NORMal]:VALue?
RECall Group
:RECall?
:RECall:INTerval
:RECall:PANel
:RECall[:STATe]
RELay Group
:RELay?
:RELay:DISPlay
:RELay:HCHannel<x>?
:RELay:HCHannel<x>:FUNCtion
:RELay:HCHannel<x>:THReshold
:RELay:MODE
:RELay:NCHannel<x>?
:RELay:NCHannel<x>:FUNCtion
:RELay:NCHannel<x>:THReshold
:RELay[:STATe]
SAMPle Group
:SAMPle?
:SAMPle:HOLD
:SAMPle:RATE
STATus Group
:STATus?
:STATus:CONDition?
:STATus:EESE
:STATus:EESR?
:STATus:ERRor?
:STATus:FILTer<x>
:STATus:QMESsage
:STATus:SPOLl?(Serial Poll)
IM 760401-01E
Description
{integration time|MATH}.
Queries communication output settings of the normal measurement function. 14-31
Sets the communication output items concerning all elements or S ON/
OFF at once.
Sets/queries the communication output items concerning each element
ON/OFF.
Sets/queries the communication output items concerning S ON/OFF.
Queries normal measured/computed data set by commands other than
"MEASure[:NORMal]:ITEM" (ASCII format).
Queries all settings related to recalling data.
Sets/queries the recalling interval.
Retrieves the setup parameters file.
Sets/queries recalling ON/OFF.
Queries all settings related to the comparator function.
Sets/queries the comparator display OFF, or in case of ON, the channel
to be displayed.
Queries all settings related to relay output items in case of harmonic
measurement.
Sets/queries function of the relay output item in case of harmonic measurement. 14-38
Sets/queries the threshold level for the relay output item.
Sets/queries the mode of the comparator function.
Queries all settings related to the relay output items in case of normal
measurement.
Sets/queries the function of the relay output in case of normal
measurement.
Sets/queries the threshold level for the relay output item.
Sets/queries the comparator function ON/OFF.
Queries all settings related to sampling.
Sets/queries to hold the output of data (display, communication).
Sets the display update rate or queries the current setting.
Queries all settings related to the status of communication.
Queries the contents of the condition filter.
Sets/queries the extended event register.
Queries the contents of the extended event register and clears it.
Queries the occurred error code and message.
Sets/queries the transit filter.
Sets/queries whether or not to apply the corresponding message to the
query "STATus:ERRor?".
Executes serial polling.
14.3 Commands
Page
14-31
14-31
14-31
14-31
14-31
14-36
14-36
14-36
14-36
14-37
14-37
14-37
14-38
14-38
14-38
14-38
14-38
14-38
14-39
14-39
14-39
14
14-40
14-40
14-40
14-40
14-40
14-40
14-41
14-41
14-13

Advertisement