YOKOGAWA WT210 User Manual page 203

Digital power meter
Table of Contents

Advertisement

Query
RR? <terminator>
Example
RR0,0,0
Description • Parameter error 12 will occur if an illegal
value is set.
• If the recalling interval is set to 0 h 0 min 0 s,
the recalling interval is set to the display
update rate as when the data was stored.
• While recalling or storing is in progress,
execution error 19 will occur.
RT/RT?
Sets the rated integration time when
integrated values are to be output as an
analog signal/inquires about the current
setting.
Syntax
RT m1,m2, m3 <terminator>
"m1" indicates the hours
0 ≤ m1 ≤ 1000
"m2" indicates the minutes
0 ≤ m2 ≤ 59
"m3" indicates the seconds
0 ≤ m3 ≤ 59
Query
RT? <terminator>
Example
RT1,0
Description • Parameter error 12 will occur if an illegal
value is set.
• The maximum time that can be specified is
10000 (hours).
RV/RV?
Sets voltage range/inquires about the
current setting.
Syntax
RV m <terminator>
"m" indicates voltage range.
• When the crest factor is set to 3
m= 3: 15V range
4: 30 V range
5: 60 V range
6: 100 V range
7: 150 V range
8: 300 V range
9: 600 V range
• When the crest factor is set to 6
m= 3: 7.5 V range
4: 15 V range
5: 30 V range
7: 75 V range
8: 150 V range
9: 300 V range
Query
RV? <terminator>
Example
RV9
Description • Parameter error 12 will occur if an illegal
value is set.
• Changing of the voltage range is not allowed
while integration is in progress; execution
error 13 will occur.
• While recalling or storing is in progress,
execution error 19 will occur.
SA/SA?
Sets the external sensor scaling value/
inquires about the current setting.
Syntax
When CM0 is set:
IM 760401-01E
SA n <terminator>
When CM1 is set:
SA m,n <terminator>
"m" indicates element.
m= 0: All elements (Setting not
allowed during inquiry)
1: Element 1
2: Element 2 (for WT230 model
760503 only)
3: Element 3 (for WT230 only)
"n" indicates external sensor
scaling value.
0.001 ≤ n ≤ 9999
Query
When CM0 is set:
SA? <terminator>
When CM1 is set:
SAm? <terminator>
Example
When CM0 is set:
SA50.00
When CM1 is set:
SA1,50.00
Description • Parameter error 12 will occur if "m" is set to
an illegal value.
• Error 12 will occur when an inquiry is made if
the shunt current values set for each element
by CM0 differ from each other.
• While recalling or storing is in progress,
execution error 19 will occur.
SC/SC?
Determines whether or not to use the
scaling function/inquires about the
current setting.
Syntax
SC m <terminator>
"m" indicates whether scaling is ON
or OFF.
m= 0: OFF
1: ON
Query
SC? <terminator>
Example
SC1
Description • Parameter error 12 will occur if "m" is set to
an illegal value.
• While recalling or storing is in progress,
execution error 19 will occur.
SI/SI?
Sets the display update rate/inquires
about the current setting.
Syntax
SI m <terminator>
"m" indicates the display update rate.
m= 0: 0.1 s
1: 0.25 s
2: 0.5 s
3: 1 s
4: 2 s
5: 5 s
Query
SI? <terminator>
Example
SI1
Description • Parameter error 12 will occur if "m" is set to
an illegal value.
13.1 Commands
13
13-13