YOKOGAWA WT210 User Manual page 158

Digital power meter
Table of Contents

Advertisement

9.9 Outputting to an External Plotter / Printer
Explanation
9-22
Selecting the Output (Printing) Mode
Select whether you are printing out on a plotter or a printer.
HPGL: For printing on an external, HPGL - compatible plotter.
ESCP: For printing on an external, ESC / P - compatible printer.
PCL : For printing on an external, PCL5 (printer language of HP) - compatible printer.
Setting the Output Contents in case of Normal Measurement
All measured and computed data is output. However, for frequency, if either one of the
display function, V Hz or A Hz, is turned on, the frequency of the corresponding function
is output. If both display functions are OFF, the voltage frequency of the element
assigned to display C is output.
Setting the Output Items and the Element in case of Harmonic Measurement
• Selecting the Output function (correspons to column A in the procedure)
One of the following items should be select, which then will be printed out on an
external plotter/ptinter. The initial value is V.
• V: Prints the numerical values of the measured values and relative harmonic
content of the voltage;
• A: Prints the numerical values of the measured values and relative harmonic
content of the current;
• P: Prints the numerical values of the measured values and relative harmonic
content of the active power;
• dEG: Prints the numerical values of the phase angle;
• G-V: Prints the numerical values
• G-A: Prints the numerical values
• G-P: Prints the numerical values
values;
• G-Vd: Prints the numerical values
each voltage of the 2nd to 50th order and the fundamental (1st order);
• G-Ad: Prints the numerical values
each current of the 2nd to 50th order and the fundamental (1st order);
• CG-V: Prints the numerical values
content of voltage;
• CG-A: Prints the numerical values
content of current;
• CG-P: Prints the numerical values
content of active power;
• ALL: Prints the numerical values
relative harmonic content of voltage and current (V and A are both printed).
*
HPGL/PCL plotters print both numerical values and the graph, but ESCP printers only
print the graph.
• Setting the Element (correspons to column B in the procedure)
One of the following should be selected. The output items corresponding to the set
element will then be printed out on an external plotter. The initial value is 1. On
the WT210, this setting is always 1.
• 1: Select this when the output items of element 1 should be printed out;
• 2: Select this when the output items of element 2 should be printed out; This
setting is not available on model 760502.
• 3: Select this when the output items of element 3 should be printed out.
Executing Output
After connecting the external plotter/printer to the WT210/WT230, execute the output.
dATA: All data selected as output items will be output.
PnL: All set-up parameters will be output.
*
and the graph of the measured voltage values;
*
and the graph of the measured current values;
*
and the graph of the measured active power
*
and the graph of the phase angle between
*
and the graph of the phase angle between
*
and the graph of the relative harmonic
*
and the graph of the relative harmonic
*
and the graph of the relative harmonic
*
and the graph of the measured values and
IM 760401-01E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt230

Table of Contents