Mazda 626 1989 Workshop Manual page 434

Hide thumbs Also See for 626 1989:
Table of Contents

Advertisement

N um ber: 0 0 3 /9 3
D IA G N O S T IC P R O C E D U R E S
B ecause of their design, m aintenance free batteries m ust not be diagnosed using procedures d eveloped for
lead storage batteries.This will provide a false reading an d result in unnecessary replacem ent.
T he table below should be followed w hen diagnosing m aintenance free batteries.
| M eas u re the cpen circuit voltage of th e battery with a digital volt m eter cap able of reading 0 .0 1 V
N O T E : Quick charge th e battery by setting
the ch arg e rate at th e "highest" or
"boost" position.
P age 2 of 3
D ate Issued: 9 /1 5 /9 3
Below 12.4 V
LOAD TEST SPECIFICATION
Approx. Battery Temp.
R evised:
Min. Volts
2 1 C (70F)
9.6
15C (60F )
9.5
10C (50F )
9.4
4 C (4 0 F )
9.3
-1 C (30 F )
9.1
-7 C (20F )
8 .9
-1 2 C (10F )
8.7
-1 8 C (OF)
8.5
1 2 .4 V and Above