WATER PUMP
INSTALLATION
Install in the reverse order of removal referring to th
installation note.
Installation Note
Rubber seal
Install the rubber seals on the water pump.
76G03A-017
Water pump
1. Remove any gasket fragments, dirt, or oil from th
contact surfaces.
2. Install a new O-ring on the water pump.
3. Install the water pump.
. Tightening torque:
19—25 N m (1.9—2.6 m-kg, 14—19 ft-lb)
Note
To prevent dropping the O-ring when instal
ing, put silicon sealant in the O-ring groov
(shaded areas) as shown. Do not apply it t
the contact surfaces.