Fault diagnosis
Analytical charts
Bravo-Btava
55D.
The right front central locking motor is not working
Extract connectors 112 and
36
from
their
housings,
bridge the H/G coloured ca
bles at the central locking
control unit connector 112
and insert an ohmmeter be
tween the H/G coloured ca
bles for connector 36
Not OK
Restore the continuity for
the H/G coloured cables be
tween the ultrasound w e l d
ing and the connector 36
OK
Extract connectors 36 and
111 from their
housings,
bridge the
H/G
coloured
cables at connector 36 and
insert an ohmmeter between
the H/G coloured cables at
the lock 111 connector
Not OK
Restore the continuity for
the H/G coloured cables be
tween the connector 36 and
the lock 111
OK
Check the condition of the
right front central locking
motor 111
Not OK
Overhaul or replace the cen
tral locking motor 111
The left rear central locking motor is not working (Non existent for the Bravo versions)
Extract connectors 112 and
86
from
their
housings,
bridge the H/G coloured ca
bles at the central locking
control unit connector 112
and insert an ohmmeter be
tween the H/G coloured ca
bles at connector 86
Not OK
Restore the continuity for
the H/G coloured cables be
tween the ultrasound w e l d
ing and the connector 86
OK
70
Print no.
506.670/02