1 . Checking current intensity
- Fit the ammeter plierson the alternator ca­
ble/junction unit
- start up the engine and let it run at be­
tween 3000 and 4000 rpm;
- switch on all the available consumers;
- measure the maximum current intensity
supplied on the multimeter display.
If this value is more than 5A below the rec­
ommended figure, overhaul the alternator.
2. Checking voltage
- Place the multimeter probes in contact
with the battery terminals;
- start up the engine and let it run at be­
tween 3000 and 4000 rpm;
- gradually switch on several consumers
until the absorbtion is about half the maxi­
mum load.
Under these circumstances the voltage read­
ing should be between the maximum and
minimum values (see diagrams) depending
on the ambient temperature of the electronic
regulator (alternator).
-40 -20
0 +20 +40 +60 +80 + 1 0 0 ° C
P4A113L07
B
Diagram A refers to an
RT 121A electronic reg­
ulator which is incorpo­
rated in M. Marelli alter­
nators, whilst diagram
B refers to the EL 14V
4C electronic regulator
which is incorporated in
Bosch alternators.