Fault diagnosis
Analytical charts
Brava
55D.
Not OK
Bridge the N coloured ca
bles at the electric windows
control panels 78 & 79 with
an earth
Not OK
Overhaul or replace panels
78 & 7 9
OK
Bridge the N coloured cable
at connector 35 with an
earth
Not OK
Restore
continuity
of
N
coloured cable btwn con
nector 35 & con. panel 80
OK
Check
condition
of
N
coloured cable btwn con.
35 & earth on dash 22
Not OK
Restore the continuity of the
N coloured cables
The left rear electric window is not working when operated by the left front panel
Check for voltage at the RN
coloured cable for the elec
tric window control panel
78
Not OK
Restore continuity for RN
coloured cable btwn panel
78 & electric windows in
hibiting button 80
OK
Check the condition of the
electric
window
control
panel 78
Not OK
Overhaul or replace the pan
el 78
38
Print no.