Panasonic Foma p705im Instruction Manual page 542

Table of Contents

Advertisement

AT command
AT¢DGPIR=n
This command is valid at dialing/
receiving calls.
In the dial-up network setting,
you can add "186" (notify) or
"184" (not notify) to the phone
number of the access point.
[M]
(See page 23 or page 43)
AT¢DRPW
Displays the output power index
for receiving.
(0: minimum value to 75:
[AT][M]
maximum value)
+++
Changes to the online command
state without disconnecting the
line when the escape sequence
[M]
is executed in the online mode.
AT+CAOC
Displays the charging
information for now or latest call.
[M]
AT+CBC
Displays the battery level.
[M]
AT+CBST=n,1,0
Sets the bearer service to be
used.
[M]
[&W][&F]
AT+CDIP=n
Sets whether to display
"Received sub-address" on your
personal computer when you
receive a call.
[M][AT]
[&F][&W]
AT+CEER
Displays the reason why the
preceding call was disconnected.
[M]
AT+CGDCONT
Sets the access point name
(APN) for when dialing for packet
[M]
communication.
AT+CGEQMIN
Registers the reference value to
judge whether the system
permits QoS (Quality of service)
reported from the network at
establishment of the packet
[M]
communication.
AT+CGEQREQ
Sets QoS (Quality of service) to
be requested to the network at
dialing of the packet
communication.
[M]
AT+CGMR
Displays the version of the
FOMA phone.
[M]
Outline
n=0: Uses the APN as it is. (default)
n=1: Adds "184" to the APN. (always not notify)
n=2: Adds "186" to the APN. (always notify)
AT¢DGPIR?: Displays the current setting.
Result: +CAOC:"n"
n: Displays the charging information in a hexadecimal
number.
Result: +CBC:n,m
n=0: FOMA phone is powered by the battery.
n=1: During charging
n=2: The battery is not connected.
n=3: Power-supply error
m=0 100: Battery level
n=116: 64000 bps (bit transparent) (default)
n=134: 64000 bps (multimedia)
n=0: Does not display "Received sub-address" when
you receive a call. (default)
n=1: Displays "Received sub-address" when you
receive a call.
Result: +CDIP:<n>,<m>
m=0: Not signed up for Multi Number
m=1: Signed up for Multi Number
m=2: Unknown
<report>
Disconnection reason list (See page 56)
See page 55.
AT+CGEQMIN=[parameter]
See page 55.
AT+CGEQMIN=?
Lists the settable values.
AT+CGEQMIN?
Displays the current setting.
AT+CGEQREQ=[parameter]
See page 55.
AT+CGEQREQ=?
Lists the settable values.
AT+CGEQREQ?
Displays the current setting.
49
Parameter/Explanation
Command execution
example
AT¢DGPIR=0
OK
AT¢DGPIR?
¢DGPIR:0
OK
AT¢DRPW
¢DRPW:0
OK
AT+CAOC
+CAOC:"00001E"
OK
AT+CBC
+CBC:0,80
OK
AT+CBST=116,1,0
OK
AT+CBST?
+CBST:116,1,0
OK
AT+CDIP=0
OK
AT+CDIP?
+CDIP:0,1
OK
AT+CEER
+CEER:36
OK
See page 55.
See page 55.
See page 55.
AT+CGMR
1234512345123456
OK

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prosolid m

Table of Contents