Vacuum Check
Tools required:
•
Magnetic screwdriver
•
Vacuum gauge
•
T-20 TORX tip
•
T-15 TORX tip
•
T-connector for vacuum gauge
•
PC diagnostics
Use this check to verify the actions of the vacuum pump and the
solenoid valve. In addition, you can determine if the cap/wipe/purge
assembly is sealing properly against the printhead faceplate.
1. Turn off the printer.
2. Remove the top and right-side covers.
3. With a T-connector, connect the vacuum gauge to the between
the vacuum/pump module and the cap/wipe/purge unit.
Adjustments 4-31