occur.
NOTE: Some service actions could leave the tilt arm in the wrong
location to allow a normal power up. This is especially true in
replacing the Printhead. When this happens, unusual noise and a loud
slam may occur after which the tilt system will recover properly. This
happens as the tilt arm struggles past the ship restrain tab. A quick
power down and power up will verify normal operation has been
resumed. To prevent the slam condition, position the head near the
center of the X-axis travel before turning on the printer.
Mounting the Digital Indicator Gauge
Mount the Digital Indicator Gauge
The digital indicator gauge must be mounted properly to obtain
stable printhead-to drum spacing readings. Use the mounting holes,
post and screw provided on the chassis when mounting the gauge.
Refer to Figure 4-6 to mount the gauge.
When installing the digital indicator gauge, push forward on the
gauge's mounting bracket so it is tight against the hex screw and the
upper screw in the chassis, and then tighten the upper chassis screw.
The gauge brack must be tight against the mounting post.
While installing the tilt arm bracket, push forward on the bracket so
Adjustments 4-17