Mitsubishi 00JCPU User Manual page 281

Q series programmable controller
Table of Contents

Advertisement

Error
Diagnostics
message
Memory copy
MEM.COPY
function
EXE.
execution
Tracking
Redunda
setting
TRK.PARA.
nt system
parameter
ERROR
error
error
Multiple CPU
CPU LAY
system not
ERROR
configurable
Another CPU
MULTI CPU
major error
DOWN
Multiple CPU
MULTI
systems
EXE.ERRO
execution
Multiple
R
error
CPU
system
Multiple CPU
CPU
error
systems
LAY.ERRO
consistency
R
error
Another CPU
MULTI CPU
minor error
ERROR
Annunciator check
F****
<CHK>ERR
CHK instruction check
***-***
Boot OK
BOOT OK
*1: The operation status can be changed to "Continue" with the parameter setting in GX Developer.
(The default is set to "Stop".)
*2: This option can be set "not checked" (set "checked" by default) with the parameter setting of GX Developer. Also, this option is not
checked while SM251 is on.
*3: This option can be set "not checked" (set "checked" by default) with the parameter setting of GX Developer.
*4: In multiple CPU systems, when the serial numbers of all the CPU modules (first five digits) are "07032" or later, this error is detected from
the CPU No.1 only.
*5: The CPU module function version B or later supports the detection of this error.
*6: Since this diagnostics indicates CPU module status, the error message is not displayed in the "Current Error" field on the PLC
diagnostics screen of GX Developer.
This error is displayed in the Error history field only.
When the Redundant CPU is used, the details of an error occurred in the other system are stored in the special relays
(SM1610 to SM1626) and special registers (SD1610 to SD1636) except when:
• the other system is during off, reset, or hardware failure,
• "WDT ERROR" (error code: 5000, 5001) is detected, or
• tracking cable has an error (not connected, disconnection, or failure).
Table6.27 Self-diagnostics list (continued)
CPU
Diagnostic timing
module
status
• Execution of the memory
Continue
copy function
• Power-on/reset
Stop
• Power-on/reset
Stop
• Always
Stop
• Power-on/reset
• Power-on/reset
Stop
• Power-on/reset
Stop
• Always
Continue
• Execution of an
Continue
instruction
• Execution of an
Continue
instruction
• Power-on/reset
Stop
: Self-diagnostics is performed,
LED status
Basic
High
model
Performance
RUN
ERR.
QCPU
model QCPU
On
On
Off
Flashing
Off
Flashing
Off
Flashing
Off
Flashing
Off
Flashing
On
On
USER
On
LED turns
on.
USER
On
LED turns
on.
Off
Flashing
: Self-diagnostics is not performed
CHAPTER6 FUNCTIONS
Process
Redundant
CPU
CPU
6 - 101
1
2
3
4
5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents