Mitsubishi 00JCPU User Manual page 347

Q series programmable controller
Table of Contents

Advertisement

(5) Device
Number of points and latch range are set for each device.
Parameter
Item
No.
*1
2000
Device points
Latch (1) start/end (Latch
2001
clear valid)
Latch (2) start/end (Latch
2002
clear invalid)
*1: When changing the device points, new setting must not exceed the refresh ranges of network modules or the auto refresh ranges of
intelligent function modules.
If a new device point setting exceeds the corresponding device range, the data may be written to another device or an error may occur.
Figure 8.5 Device
Table8.5 Device setting list
Description
Set the number of device points that
H
is appropriate to the system.
Set a latch range (start and end
device numbers), which can be
H
cleared by remote latch clear
operation.
Set a latch range (start and end
device numbers), which cannot be
H
cleared by remote latch clear
operation.
Setting range
X(2K), Y(2K), S(2K), SB(1K), and
SW(1K) are fixed.
Setting is available within the range
of 16.4K words in total, including the
above fixed points (1.5K words).
One device: Up to 32K points
(No restrictions on the total points
for bit devices.)
Setting is available for only one
range for each of B, F, V, T, ST, C,
D, and W devices.
Setting is available for only one
range for each of L, B, F, V, T, ST, C,
D, and W devices.
CHAPTER8 PARAMETERS
Default
Reference
• X: 2K
• Y: 2K
• M: 8K
• L: 2K
• B: 2K
• F: 1K
• SB: 1K
Section 9.1,
• V: 1K
Section 9.2
• S: 2K
• T: 512
• ST: 0K
• C: 512
• D: 11136
• W: 2K
• SW: 1K
Section 3.7,
Blank
Section 6.3
Section 3.7,
Blank
Section 6.3
8 - 6
1
2
3
4
5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents