(b) I/O assignment
Select "32 points" for the number of I/O points of Slot 3 in the I/O assignment setting of PLC parameter in GX
Developer.
Select 32 points. (When
the type is not selected,
the type of the mounted
module will be set.)
Figure 4.12 I/O assignment setting (When changing points of Slot 3)
(c) I/O number assignment after the I/O assignment using GX Developer
The number of I/O points is
changed from 16 points to
32 points.
Extension
1
Figure 4.13 I/O numbers after I/O assignment (After changing points of the empty slot)
Q38B
0
1
32
32
points
points
X00 X20
to
to
X1F X3F X5F
Q68B
8
9
32
32
points
points
100
120
to
to
11F
13F
CHAPTER4 ASSIGNMENT OF BASE UNIT AND I/O NUMBER
2
3
4
5
6
32
32
32
32
32
points
points
points
points
points
X40
60
Y80 YA0 YC0 YE0
to
to
to
to
to
7F
Y9F YBF YDF YFF
10
11
12
13
14
32
32
32
32
32
points
points
points
points
points
140
160
180 Y190 Y1B0 Y1D0
to
to
to
to
to
15F
17F
18F Y1AF Y1CF Y1EF
7
Slot number
32
Number of I/O
points
points
to
I/O number
15
32
points
to
4 - 15