(b) When a A series interrupt module is mounted
Table9.16 List of interrupt pointer numbers and interrupt factors (High Performance model QCPU)
I No.
Interrupt factor
I0
I1
I2
I3
I4
I5
I6
Interrupt by interrupt
I7
module (A1SI61)
I8
I9
I10
I11
I12
I13
I14
I15
I16
I17
I18
I19
I20
Interrupt by a
I21
sequence-started
I22
*1
module
I23
I24
I25
I26
I27
I28
I29
Interrupt by
*2
I30
internal timer
I31
9 - 89
Priority
1st point
220
2nd point
221
3rd point
222
4th point
223
5th point
224
6th point
225
7th point
226
8th point
227
9th point
228
10th point
229
11th point
230
12th point
231
13th point
232
14th point
233
15th point
234
16th point
235
1st module
208
2nd module
209
3rd module
210
4th module
211
5th module
212
6th module
213
7th module
214
8th module
215
9th module
216
10th module
217
11th module
218
12th module
219
100ms
239
40ms
238
20ms
237
10ms
236
I No.
Interrupt factor
*5
I32
I33
I34
Interrupt by an
I35
*5 *6
error
I36
I37
I38
I39
I40 to
48
Interrupt by
I49
internal timer
Intelligent
I50 to
function module
255
interrupt
*8 *9
Priority
All of stop errors
SINGLE PS. DOWN
*3 *4
UNIT VERIFY ERR.,
FUSE BREAK OFF,
SP. UNIT ERROR,
MULTI CPU ERROR
OPERATION ERROR,
SFCP OPE. ERROR,
SFCP EXE. ERROR,
EX.POWER OFF
ICM. OPE ERROR,
FILE OPE. ERROR
Empty
PRG. TIME OVER
CHK instruction
execution,
annunciator detection
Empty
*7
0.2ms to 1ms
Specify the intelligent
function module or
2 to 207
interrupt module (QI60)
with a parameter.
1
*10