3-6 Parameter Unit Specifications
The Parameter Unit is required for parameter setting and monitoring for the Servo Drive.
R88A-PR02G Hand-held Parameter Unit
General Specifications
Operating ambient temperature
Operating ambient humidity
Storage ambient temperature
Storage ambient humidity
Operating and storage
atmosphere
Vibration resistance
Performance Specifications
Item
Type
Cable length
Connectors
Display
External dimensions
Weight
Standard
Communications method
Baud rate
Start bits
Data
Parity
Stop bits
Item
0 to 55°C
90% RH max. (with no condensation)
−20 to 80°C
90% RH max. (with no condensation)
No corrosive gases
2
5.9 m/s
Hand-held
1.5 m
Mini DIN 8P MD connector
7-segment LED
62 (W) × 114 (H) × 15 (D) mm
Approx. 0.1 kg (including cable)
RS-232
Asynchronous (ASYNC)
9,600 bps
1 bit
8 bits
None
1 bit
3-6 Parameter Unit Specifications
Specifications
max.
Specifications
3