7 Other Functions
7-5-5
RUN Direction Limit Selection
Use this function to limit the RUN direction of the motor.
It can be activated either via the control circuit terminal block or the Digital Operator.
When the inverter receives a RUN command input with the RUN direction limit function enabled from
the control circuit terminal block,
Parameter
No.
RUN Direction Limit
b035
Selection
7-5-6
Permission of RUN Command
Use this function to have the inverter accept the RUN command only while the permission of RUN com-
mand is ON.
To use it, set the Multi-function Input S1 to S7 Selection (C001 to C007) to 84 (ROK).
Parameter
No.
Multi-function Input S1 to
C001 to
C007
S7 Selection
Output
frequency
ROK input
RUN command
FW/RV input
7 - 38
Function name
00:
No direction limit
01:
Only Forward is enabled (Motor does not
rotate in reverse.)
02:
Only Reverse is enabled (Motor does not
rotate in forward.)
Function name
84:
is displayed on the Digital Operator.
Data
Data
ROK (Permission of RUN command)
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Default
Unit
data
−
00
Default
Unit
data
−
−