Monitor Function/Enter Command Register List - Omron MX2 Series User Manual

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

8-9-2

Monitor Function/Enter Command Register List

Precautions for Correct Use
• The "Register No." in the table header shows the register number used inside the inverter.
Use this register number when setting the communications option unit (EtherCAT/Compo-
Net/DeviceNet) for the inverter.
• The "Modbus register spec. No." in the table header shows the register number used to actu-
ally specify the register in the Modbus communication process.
This register number is 1 less than the inverter "Register No." according to the Modbus com-
munication specifications.
Register
Modbus register
No.
spec. No
0000 hex
0001 hex
0000 hex
0002 hex
0001 hex
0003 hex
0002 hex
0004 hex
0003 hex
0005 hex
0004 hex
*1. When the PID function is enabled, the data unit differs between read and write operations. Set parameter val-
ues in units of 0.01 Hz for writing and in units of 0.01% (as 100% of the maximum frequency) for reading.
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Function name
Reserved
Output Frequency
Setting/Monitor
Inverter Status A
Inverter Status B
Inverter Status C
8 Communications Functions
Monitor or setting
Parameter No.
R/W
F001 (HIGH)
R/W 0 to Maximum fre-
quency (Enabled
F001 (LOW)
R/W
when A001 = 03)
0:
2:
3:
4:
R
5:
6:
8:
9:
0:
R
1:
2:
0:
1:
2:
3:
4:
5:
6:
R
7:
8:
9:
10:
Data
data
resolution
0.01
*1
[Hz]
Initial status
Stop
Run
Free-run stop
Jogging
DC injection
braking
Trip
During UV
During stop
During RUN
During trip
Stop
Deceleration
Constant
speed
Acceleration
Forward
Reverse
Forward to
reverse
Reverse to
forward
Forward run
start
Reverse run
start
8 - 41
8