Omron MX2 Series User Manual page 263

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

Complementary Output
(Model: E6C3-CWZ5GH)
Wiring for Single-phase Pulse Signal and Direction Signal (P004 = 01 or 03)
Connect the single-phase pulse signal or single-phase pulse + direction signal as shown in the diagram
below.
• Connect the single-phase pulse signal to the pulse train input RP terminal.
• Input the direction signal to the multi-function Input S7 terminal and set the Multi-function Input S7
Selection (C007) to 85 (EB: Rotation direction detection). Select the sink logic (NPN) or source (PNP)
by properly positioning the short-circuit bar.
• The control circuit terminal P24 of the inverter is for a 24-V, 100-mA max. power supply. It can be
used for the encoder power supply if the consumption current for the input terminals in use and the
encoder power supply is allowable. However, this terminal must be isolated from any 24-V system
power supply for other than the encoder and inverter.
Complementary-output type encoder
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
24-V power
24-V power
supply (Brown)
supply
7.5 Ω
Phase A
(Black)
24 Ω
Phase B
(White)
7.5 Ω
GND (Blue)
Encoder
6 Vector Control and Applied Functions
3G3MX2 Series Inverter
P24
RP
3.9 kΩ
5.1 V
S7
4.7 kΩ
4.7 kΩ
S1 to S6
PSC
SC
P24
Vcc
RP
Out
Direction
S7
PSC
SC
GND
510 Ω
6.2 kΩ
3G3MX2
6 - 21
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents