Inverter Display on Operator Connection

When the inverter is connected with the optional Digital Operator (Model: 3G3AX-OP01), the built-in
Digital Operator keys are disabled. Use this function to set the parameter to display on the built-in Digi-
tal Operator at this time.
Parameter
No.
Inverter Display on
b150
Operator Connection
7-6-8

Display Fixed (DISP)

Setting the Multi-function Input S1 to S7 Selection (C001 to C007) to 86 (DISP) and turning ON the cor-
responding terminal causes the Digital Operator to display only the content selected in the Initial Screen
Selection (b038), preventing it from displaying other parameters.
Parameter
No.
Multi-function Input S1
C001 to
C007
to S7 Selection
Related functions
7-6-9

Password Function

Use the password function to set passwords for the Display Selection (b037) and Soft Lock Selection
(b031) functions to prevent display and change of the parameter settings.
Parameter
No.
Password A
b190
Setting
Password A for
b191
Authentication
Password B
b192
Setting
Password B for
b193
Authentication
Related functions
*1. These passwords cannot be set to 0000.
*2. You can use any of the following 16 (hex) characters for parameter setting: 0 to 9, A, b, C, d, E, F.
Precautions for Correct Use
Be sure not to forget the set password. Note that there is no way to reset the password lock
once you forget the set password and even OMRON factories and service stations have no
means to check your password.
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Function name
001 to 060
Each data corresponds with the monitor mode
parameters d001 to d060.
Function name
86:
DISP (Display fixed)
b038
Function
Data
name
0000
0001 to FFFF
0000 to FFFF
0000
0001 to FFFF
0000 to FFFF
b031, b037
Data
Data
Description
*1
Password function disabled.
Set the password A for the Display
*2
Selection (b037).
Set the password A authentication
*2
parameter.
*1
Password function disabled.
Set the password B for the Soft Lock
*2
Selection (b031).
Set the password B authentication
*2
parameter.
7 Other Functions
Default
Unit
data
001
Default
Unit
data
Default
Unit
data
0000
0000
0000
0000
7 - 57