7-8-11 Logic Operation Output Signal (LOG1 to LOG3)

Use these signals to have the inverter internally perform logical operations with output signals. Set the
Multi-function Output P1/P2 Selection (C021/C022), or Multi-function Relay Output (MA, MB) Function
Selection (C026), to 33 (LOG1: Logic operation output 1), 34 (LOG2: Logic operation output 2), or 35
(LOG3: Logic operation output 3). The logic output signal selection parameters cannot be set to 255
(no: No allocation), 63 (OPO: Option), or 33 to 35 (LOG1 to LOG3: Logic operation output 1 to 3).
Three operators, AND, OR, and XOR, are available.
Logic output sig-
nal selection 1
Logic output sig-
nal selection 2
LOGx (AND)
LOGx (OR)
LOGx (XOR)
Each logic operation output signal requires different parameter settings.
Set the necessary parameters according to the table below.
Selected signal
33:
Logic operation output 1 (LOG1)
34:
Logic operation output 2 (LOG2)
35:
Logic operation output 3 (LOG3)
(Example) To output the result of the AND operation between RUN (00: Signal during RUN) and FA2
(01: Set frequency exceeded signal) to the multi-function output terminal P2 as a logic oper-
ation output 1 (LOG1) terminal
Multi-function Output P2 Selection (C022)
Logic Output Signal 1 Selection 1 (C142)
Logic Output Signal 1 Selection 2 (C143)
Logic Output Signal 1 Operator Selection (C144) : 00 (AND)
RUN
FA2
LOG1
Parameter
No.
C142
Logic Output Signal 1 to 3
C145
Selection 1
C148
C143
Logic Output Signal 1 to 3
C146
Selection 2
C149
C144
Logic Output Signal 1 to 3
C147
Operator Selection
C150
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Logic output sig-
nal selection 1
Function name
00 to 63: Same as options for C021
(Except 33 (LOG1) to 35 (LOG3), 63
(OPO), and 255 (no))
00:
01:
02:
Logic output sig-
nal selection 2
C142
C143
C145
C146
C148
C149
: 33 (LOG1)
: 00 (RUN)
: 02 (FA2)
Data
AND
OR
XOR
7 Other Functions
Operator selec-
tion
C144
C147
C150
Default
Unit
data
00
00
00
7 - 83
7