5-2 Basic Functions
An overview of run/stop operations using the FW/RV terminals is shown below.
Output frequency
Forward direction
Reverse direction
RUN lamp
Forward command
FW input
Reverse command
RV input

RUN Direction Selection

Select the rotation direction to be applied when a RUN command is input from the Digital
Operator or external Digital Operator.
5
Becomes invalid when any RUN command issued from the control circuit terminal block or
Remote Operator.
Parameter
F004

Rotation Direction Limit Selection

Limits motor rotation directions.
Enabled in either "control circuit terminal block" or "Digital Operator" control mode.
When a limited RUN command is input from the control circuit terminal block, the Digital
Operator displays
Parameter
b035
5-23
ON
ON
OFF
Function name
No.
RUN Direction
Selection
.
OkOkOkO
Function name
No.
Rotation Direction
Limit Selection
Output frequency setting
OFF
Data
00: Forward operation
01: Reverse operation
Data
00: No direction limit
01: Only Forward is enabled
(No Reverse)
02: Only Reverse is enabled
(No Forward)
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
ON
OFF
ON
Default
setting
00
Default
setting
00
Time