Group H: Motor Control Parameters - Omron MX2 Series User Manual

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

4 Parameter List
4-3-4

Group H: Motor Control Parameters

Parameter
Function name
No.
H001
Auto-tuning Selection
1st Motor Parameter
H002
selection
2nd Motor Parameter
H202
Selection
H003
1st Motor Capacity
H203
2nd Motor Capacity
H004
1st Motor Pole Number
2nd Motor Pole Num-
H204
ber Selection
H005
1st Speed Response
H205
2nd Speed Response
1st Stabilization
H006
Parameter
2nd Stabilization
H206
Parameter
1st Motor Parameter
H020
R1
2nd Motor Parameter
H220
R1
1st Motor Parameter
H021
R2
2nd Motor Parameter
H221
R2
H022
1st Motor Parameter L
H222
2nd Motor Parameter L
H023
1st Motor Parameter Io
2nd Motor Parameter
H223
Io
H024
1st Motor Parameter J
H224
2nd Motor Parameter J
1st Motor Parameter
H030
R1
(Auto-tuning Data)
2nd Motor Parameter
H230
R1
(Auto-tuning Data)
1st Motor Parameter
H031
R2
(Auto-tuning Data)
2nd Motor Parameter
H231
R2
(Auto-tuning Data)
4 - 32
Monitor or data range
00: Disabled
01: Enabled (No motor
rotation)
02: Enabled (Motor rota-
tion)
00: Standard motor para-
meter
02: Auto-tuning data
0.1/0.2/0.4/0.55/0.75/1.1/1.5/
2.2/3.0/3.7/4.0/5.5/7.5/11.0/
15.0/18.5
2/4/6/8
10 to 48: Do not set.
1. to 1000.
0. to 255.
0.001 to 9.999
10.00 to 65.53
0.001 to 9.999
10.00 to 65.53
0.01 to 99.99
100.0 to 655.3
0.01 to 99.99
100.0 to 655.3
0.001 to 9.999
10.00 to 99.99
100.0 to 999.9
1000. to 9999.
0.001 to 9.999
10.00 to 65.53
0.001 to 9.999
10.00 to 65.53
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Setting
Default
Set
during
data
data
RUN
00
Disabled
00
Disabled
00
Disabled
Maximum
Disabled
applicable
motor
Disabled
capacity
4
Disabled
4
Disabled
100.
Enabled
100.
Enabled
100.
Enabled
100.
Enabled
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Dependent
Disabled
on capacity
Changes
during
Unit
Page
RUN
Disabled
P. 6-4
Disabled
Disabled
Disabled
kW
Disabled
kW
P. 6-4
Disabled
pole
Disabled
Enabled
Enabled
Enabled
P. 7-52
Enabled
Disabled
Disabled
Disabled
Disabled
Disabled
mH
P. 6-9
Disabled
Disabled
A
Disabled
Disabled
2
kgm
Disabled
Disabled
Disabled
P. 6-4
Disabled
Disabled

Hide quick links: