7-1-3

RUN Direction Monitor [d003]

Use this function to display the RUN direction of the inverter.
The RUN LED is lit during inverter operation (forward/reverse RUN).
Parameter
No.
d003
RUN Direction Monitor
Generally, the forward rotation is defined as the direction in which the motor rotates counterclockwise when
viewed from the shaft.
7-1-4

PID Feedback Value Monitor [d004]

Use this function to monitor the PID feedback value when the PID Selection (A071) is set to 01
(Enabled) or 02 (Reverse output enabled).
The monitor value is displayed in units of percentage as 100% of the 1st/2nd Maximum Frequency
(A004/A204) and can be converted by setting the PID Scale (A075) as follows.
d004 = Feedback value [%] × PID Scale (A075)
Parameter
No.
PID Feedback Value
d004
Monitor
A075
PID Scale
Related functions
7-1-5

Multi-function Input Monitor [d005]

Use this function to display the input status of each multi-function input terminal, based on whether the
corresponding 7-segment LED is lit or not lit.
The terminal for which the built-in CPU detected the input is indicated as ON. Note that this is indepen-
dent of the NO/NC contact setting for each multi-function input terminal.
(Example) Multi-function input terminals S7, S2, and S1
Multi-function input terminals S6, S5, S4, and S3
S7 S6 S5 S4 S3 S2 S1
(ON)(OFF)(OFF)(OFF)(OFF)(ON) (ON)
• When the input terminal response time function is enabled, the inverter cannot display the input sta-
tus immediately. (Refer to 5-9-3 Input Terminal Response Time on page 5-48.)
• The terminal S5 remains OFF and cannot be monitored when Multi-function Input S5 Selection
(C005) is allocated to 19 (TH: PTC thermistor thermal protection).
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Function name
F : Forward
o : Stop
r : Reverse
Forward
Function name
0.00 to 99.99 (Displayed in increments of 0.01)
100.0 to 999.9 (Displayed in increments of 0.1)
1000. to 9999. (Displayed in increments of 1)
1000 (Displayed in increments of 10)
0.01 to 99.99 (Set in increments of 0.01)
A071, A075
Display
ON
OFF
Data
Data
: ON
: OFF
: Lit
: Not lit
7 Other Functions
Default
Unit
data
Default
Unit
data
1.00
time
7 - 5
7