Terminal Mp (Pulse/Pwm Output) - Omron MX2 Series User Manual

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

(Example 2) A015/A165 = 01 (0 Hz)
Maximum frequency
A012/A102/A162
A011/A101/A161
7-3-6

Terminal MP (Pulse/PWM Output)

The terminal MP provides 10-VDC pulse output or PWM output.
The terminal MP on the control circuit terminal block enables the monitoring of the output frequency
and the output current.
MP Selection
Select the signal you want to output from the following table.
For pulse output signals (03, 08, 15), use a digital frequency counter. For other output signals, use an
analog meter.
Parameter
Function
No.
name
MP
C027
Selection
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
0
A013/
A014/
100%
A103/
A104/
A163
A164
(0 V)
(10 V)
(0 mA)
(20 mA)
(VR min.)
(VR max.)
Data
Description
00
Output frequency
01
Output current
*3
02
Output torque
03
Digital output frequency
04
Output voltage
05
Input power
06
Electronic thermal load rate
07
LAD frequency
08
Digital current monitor
10
Cooling fin temperature
12
DriveProgramming (YA(0))
15
Pulse train input monitor
Option (No applicable
16
Option)
Output frequency is 0 Hz for 0% to A013/A103/A163.
(A015/A105/A165 = 01 (0 Hz))
Analog input
(FV/FI)
PWM/
Pulse
*1 *2
PWM
0 to Maximum frequency [Hz]
PWM
0 to 200%
PWM
0 to 200%
*4
Pulse
0 to Maximum frequency [Hz]
0 to 133%
PWM
(Example: For 200-V class, 7.5 V
at 200 V)
PWM
0 to 200%
PWM
0 to 100%
*1
PWM
0 to Maximum frequency [Hz]
Refer to MP Gain Setting on page
Pulse
7-28.
0 to 200°C (Outputs 0°C for 0°C or
PWM
lower)
Use DriveProgramming to set this
PWM
function. (0.00 to 100.00%)
Refer to MP Gain Setting on page
Pulse
7-28.
7 Other Functions
Full-scale value
7 - 27