Input/Output Terminal Variables

This section describes the variables provided for using the following inverter terminals for the
DriveProgramming function: Input terminals, output terminals, relay outputs, analog input terminals,
and analog output terminals. Use these variables as the interface between the inverter's peripheral
devices and the DriveProgramming function.
Input Terminal Variables X(00) to X(10)
You can use the inverter's input terminals as the input terminal variables X(00) to X(10) for the Drive-
Programming function by setting these input terminals to the general-purpose input MI1 to MI11.
When Xw variables are used, the input terminal variables X(00) to X(10) can be used as word access
data.
Function
variable
X(00) to
Input terminal variable
X(10)
(bit access)
• The status of the input terminals 1 to 9, A and B is captured and set as bit-size variables. This vari-
able is read-only.
• When the input terminals 1 to 9, A and B Selection (CA-01 to CA-11) are set to 86 to 96 (MI1 to MI11:
General-purpose input), the status of the input terminals 1 to 9, A and B is captured and set as the
input terminal variables X(00) to X(10) of the DriveProgramming.
Numbers are given to the input terminal variables X(00) to X(10) according to the numerical order of
the set general-purpose inputs MI1 to MI11, not the terminal numbers 1 to 9, A and B.
Function variable
X(00)
X(01)
X(02)
X(03)
X(04)
X(05)
X(06)
X(07)
X(08)
X(09)
X(10)
DriveProgramming User's Manual (I622-E1)
Description
Data range
0: OFF
1: ON
Input Terminal (CA-01 to CA-11)
5 DriveProgramming User Variables
Default
Unit
data
0
86: MI1
87: MI2
88: MI3
89: MI4
90: MI5
91: MI6
92: MI7
93: Ml8
94: Ml9
95: Ml10
95: Ml11
Data size
R/W
bit
R
5
5 - 5